首页 | 本学科首页   官方微博 | 高级检索  
检索        


MR imaging of cartilage in cadaveric wrists: comparison between imaging at 1.5 and 3.0 T and gross pathologic inspection
Authors:Saupe Nadja  Pfirrmann Christian W A  Schmid Marius R  Schertler Thomas  Manestar Mirjana  Weishaupt Dominik
Institution:Department of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland. nadja.saupe@balgrist.ch
Abstract:PURPOSE: To evaluate prospectively the diagnostic accuracy of magnetic resonance (MR) imaging in the identification of cartilage abnormalities at 3.0 and 1.5 T in cadaveric wrists, with gross pathologic findings as the standard of reference. MATERIALS AND METHODS: The study was approved by the hospital review board, and informed consent for scientific use of body parts had been provided by the subjects. Ten cadaveric wrists from nine subjects were evaluated (seven left wrists, three right; five women, four men; age range, 46-99 years; mean age, 80 years). All wrists were examined with MR imaging in a 1.5-T unit and a 3.0-T unit, with the same imaging protocol used with both systems. Imaging protocol included intermediate-weighted fast spin-echo sequences and three-dimensional gradient-recalled-echo sequences. Cartilage surfaces of the proximal and distal carpal row, including the scaphotrapeziotrapezoidal joint, were analyzed in blinded fashion by two musculoskeletal radiologists working independently and then in consensus. Open inspection of the wrists was used as the standard of reference. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated. The McNemar test was used to assess differences in diagnostic assessment. Weighted kappa values were calculated for interobserver agreement. RESULTS: One hundred seventy cartilage surfaces were graded. The sensitivity and specificity for cartilage lesions were 43%-52% and 82%-89%, respectively, at 1.5 T and 48%-52% and 82% at 3.0 T. Differences in assessment did not reach statistical significance (P > .99). Highest sensitivities were found in the proximal carpal row (67%-71%); lowest sensitivities were found in the distal carpal row (14%-24%). Interobserver agreement was higher for imaging at 3.0 T (kappa = 0.634) than at 1.5 T (kappa = 0.267). CONCLUSION: The performance of MR imaging for the detection of articular cartilage abnormalities in the wrist depends on anatomic location. Interobserver agreement is higher for imaging at 3.0 than at 1.5 T, but diagnostic performances were not significantly different (P > .99) at either field strength.
Keywords:
本文献已被 PubMed 等数据库收录!
点击此处可从《Radiology》浏览原始摘要信息
点击此处可从《Radiology》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号