首页 | 本学科首页   官方微博 | 高级检索  
检索        

肾素、醛固酮化学发光免疫法检测的性能验证及筛查原发性醛固酮增多症的价值
引用本文:刘稚,张玫,任艳,陈涛,高洪蛟,何訸,阿衣李桂,刘英,安振梅.肾素、醛固酮化学发光免疫法检测的性能验证及筛查原发性醛固酮增多症的价值[J].四川大学学报(医学版),2021,52(3):472-476.
作者姓名:刘稚  张玫  任艳  陈涛  高洪蛟  何訸  阿衣李桂  刘英  安振梅
作者单位:四川大学华西医院实验医学科 ,成都 610041;四川大学华西医院内分泌代谢科 ,成都 610041;遵义医科大学第三附属医院内分泌科 ,遵义 563000
基金项目:四川省科学技术厅重点研发项目(No. 2020YFS0096)资助
摘    要:目的 验证化学发光免疫法(CLIA)检测肾素、醛固酮的性能及筛查原发性醛固酮增多症(原醛症)的价值.方法 根据美国临床实验室标准化协会相关文件验证CLIA检测肾素、醛固酮的精密度、线性范围和携带污染率.纳入91例疑似原醛症的患者,分别采用CLIA、放射免疫法(RIA)检测肾素和醛固酮,比较两种方法的相关性和对原醛症的筛...

关 键 词:化学发光免疫法  原发性醛固酮增多症  肾素  醛固酮
收稿时间:2021-01-07

Performance Verification of Plasma Renin and Aldosterone Examination with Chemiluminescence Immunoassay and Its Screening Efficacy for Primary Aldosteronism
LIU Zhi,ZHANG Mei,REN Yan,CHEN Tao,GAO Hong-jiao,HE He,AYILIGUI,LIU Ying,AN Zhen-mei.Performance Verification of Plasma Renin and Aldosterone Examination with Chemiluminescence Immunoassay and Its Screening Efficacy for Primary Aldosteronism[J].Journal of West China University of Medical Sciences,2021,52(3):472-476.
Authors:LIU Zhi  ZHANG Mei  REN Yan  CHEN Tao  GAO Hong-jiao  HE He  AYILIGUI  LIU Ying  AN Zhen-mei
Institution:1.Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, China
Abstract:  Objective  To evaluate the performance of chemiluminescence immunoassay (CLIA) in examining renin and aldosterone and to determine its value for screening for primary aldosteronism (PA).  Methods  According to the relevant documents of Clinical and Laboratory Standards Institute (CLSI), we verified the precision, linear range and carryover rate of examining renin and aldosterone with CLIA. The study included 91 suspected PA patients, using two methods, CLIA and radioimmunoassay (RIA), to examine renin and aldosterone levels in order to compare the correlation between the two methods and their value for PA screening.  Results  The precision, linear range and carryover rate of examining renin and aldosterone with CLIA met the requirements. In patients with suspected PA, the correlation coefficients of renin, aldosterone and aldosterone-to-renin ratio (ARR) assessed by CLIA and RIA were 0.901, 0.861 and 0.847 respectively (all P<0.001). When the patients were in the upright position and the ARR was 5.636 (ng/dL)/(ng/L), the CLIA method had 79.1% sensitivity and 93.7% specificity for PA screening; when ARR was 14.084 (ng·dL-1)/(ng·mL·h]-1), the RIA method had 93.0% sensitivity and 83.3% specificity for PA screening. When the patients were in the supine position, and the ARR was 5.640 (ng/dL)/(ng/L), the CLIA method had 97.7% sensitivity and 81.2% specificity for PA screening; when ARR was 33.494 (ng·dL-1)/(ng·mL·h]-1), RIA had 95.3% sensitivity and 70.8% specificity for PA screening .  Conclusion  The performance of the CLIA kit in assessing the concentration of renin and aldosterone meets the clinical requirements. Regarding preliminary PA screening, upright-position ARR had higher specificity, but lower sensitivity compared with supine-position ARR.
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《四川大学学报(医学版)》浏览原始摘要信息
点击此处可从《四川大学学报(医学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏