首页 | 本学科首页   官方微博 | 高级检索  
     


A custom-made prosthesis attached to an existing femoral component for the treatment of peri- and sub-prosthetic fracture
Authors:Tillman R  Kalra S  Grimer R  Carter S  Abudu A
Affiliation:Royal Orthopaedic Hospital, Bristol Road South, Birmingham, B31 2AP, UK. roger.tillman@roh.nhs.uk
Abstract:Peri- and sub-prosthetic fractures, or pathological fractures below an existing well-fixed femoral component, with or without an ipsilateral knee replacement, present a difficult surgical challenge. We describe a simple solution, in which a custom-made prosthesis with a cylindrical design is cemented proximally to the stem of an existing, well-fixed femoral component. This effectively treats the fracture without sacrificing the good hip. We describe five patients with a mean age of 73 years (60 to 81) and a mean follow-up of 47 months (6 to 108). The mean overlap of the prosthesis over the femoral component was 7.5 cm (5.5 to 10). There have been no mechanical failures, no new infections and no re-operations. We suggest that in highly selected cases, in which conventional fixation is not feasible, this technique offers a durable option and avoids the morbidity of a total femoral replacement.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏