首页 | 本学科首页   官方微博 | 高级检索  
检索        


Accuracy of a practicable EMG to force model for knee muscles
Authors:Doorenbosch Caroline A M  Harlaar Jaap
Institution:Department of Rehabilitation Medicine, VU University Hospital, P.O. Box 7057, 1007 MB Amsterdam, The Netherlands. cam.doorenbosch@vumc.nl
Abstract:A practicable EMG-force model is evaluated for muscles about the knee. The model included envelope signal processing and a gain-dependency of knee angle and angular velocity. Six healthy subjects participated in the experiments. For calibration, maximal isokinetic contractions about the knee were performed on a dynamometer with recordings of knee joint movement, net moment and EMG of thigh muscles. The model parameters were fitted on these calibration experiments. For validation, estimated moments from the EMG levels were compared to the actual exerted moments of two independent isokinetic contractions. Averaged RMS values of the difference ranged from 11 to 20% of the actual exerted moment. For isokinetic concentric contractions, the present model is suitable as a method to estimate muscle moments.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号