摘    要:目的: 建立小鼠血浆中银杏酸(ginkgolic acid,GA) 3种主要单体GA 13∶0,GA 15∶1和GA 17∶1的高效液相色谱(HPLC)测定方法。方法: 以制备的GA 13∶0,GA 15∶1和GA 17∶1单体为标准品,采用外标法建立标准曲线。采用乙腈预处理样品以沉淀其中蛋白质。采用SinoChrom ODS AP C18色谱柱 (250 mm×4.6 mm,5 μm),甲醇-3%醋酸(92∶8)为流动相,流速1.0 mL· min-1,检测波长为310 nm。结果: GA 13∶0,GA 15∶1和GA 17∶1标准曲线分别在0.135~20μg·mL-1,0.129 ~20μg·mL-1和0.211~22μg·mL-1范围内线性关系良好(r均>0.999 0);回收率均>70.2% (n=5),测定准确度为95.2%~101.5%;日内相对标准偏差≤6.2%,日间相对标准偏差≤9.5%。结论:成功建立测定GA 13∶0,GA 15∶1和GA 17∶1单体的HPLC方法,其灵敏度高,重现性、精密度和准确性好。

关 键 词:银杏酸单体   高效液相色谱法   小鼠  

High performance liquid chromatography determination method for three monomers of ginkgolic acid in mouse plasma
YANG Xiao-Ming,Shen-Jie-Hong,Li-Yue-Ying,Lin-Jian-Wei,Huang-Bing-Zhong. High performance liquid chromatography determination method for three monomers of ginkgolic acid in mouse plasma[J]. Journal of Jiangsu University Medicine Edition, 2013, 23(6): 480
Authors:YANG Xiao-Ming  Shen-Jie-Hong  Li-Yue-Ying  Lin-Jian-Wei  Huang-Bing-Zhong
Affiliation:(1.School of Food and Biological Engineering, 2.Jingjiang College, 3.School of Medical Science and Laboratory Medicine, Jiangsu University, Zhenjiang Jiangsu 212013;  4.Internal Medicine, the People′s Hospital of Dantu, Zhenjiang Jiangsu 212028, China)
Abstract:Objective: To develop a high performance liquid chromatography (HPLC) method for determining three monomers of ginkgolic acids, GA 13∶0, GA 15∶1 and GA 17∶1,  in mouse plasma. Methods: Plasma samples were treated with acetonitrile for protein precipitation. The analytical column was SinoChrom ODS AP C18(250 mm×4.6 mm, 5 μm).The mobile phase consisted of a mixture of methanol 3% acetic acid (92∶8) at a flow rate of 1.0 mL· min-1. The detection wavelength was at 310 nm. Results: Standard curves of GA 13∶0, GA 15∶1 and GA 17∶1 were linear in the range  of 0.135-20 μg·mL-1, 0.129-20 μg·mL-1, and 0.211-22 μg·mL-1, respectively (both r>0.9990). The lower limit of quantification were 0.135, 0.129 and 0.211 μg·mL-1, respectively. The extraction recoveries>70.2% (n=5) and the accuracies were 95.2%-101.5%. The intra-day and inter-day precisions were lower than 6.2% and 9.5 % (n=5), respectively. Conclusion: The HPLC method was successfully built for determining GA 13∶0, GA 15∶1 and GA 17∶1, which was simple and  sensitive, accurate with  reproducible, and suitable for clinical pharmacokinetic study.  [Key words]ginkgolic acid monomer; high performance liquid chromatography; mouse