首页 | 本学科首页   官方微博 | 高级检索  
检索        

大转子延长截骨结合生物型加长柄翻修人工髋关节
引用本文:周卫,刘东海,徐振伟,吴登科,赵世阳.大转子延长截骨结合生物型加长柄翻修人工髋关节[J].中国组织工程研究与临床康复,2014(40):6419-6424.
作者姓名:周卫  刘东海  徐振伟  吴登科  赵世阳
作者单位:平顶山市第一人民医院关节骨病科,河南省平顶山市467000
摘    要:背景:在髋关节翻修过程中移除固定良好的生物型假体柄及骨水泥柄很困难,应用大转子延长截骨能很好的解决这个问题,结合生物型加长柄能降低翻修后并发症。 目的:回顾性分析大转子延长截骨结合生物型加长柄翻修人工髋关节的近期效果。 方法:选择2008年5月至2013年5月于平顶山市第一人民医院关节骨病科进行人工髋关节翻修的25例患者,其中17例应用单切口双入路行大转子延长截骨,术中股骨重建均采用生物型翻修加长柄。随访12-60个月,记录翻修前后Harris髋关节评分、翻修后并发症,记录截骨长度、假体柄在股骨髓腔内远端固定的长度和截骨处远端至假体末端的长度。 结果与结论:17例患者均获随访,平均截骨长度17 cm(15-23 cm),平均假体柄和髓腔接触面长度为6.4 cm (4-11 cm),截骨处远端至假体末端的平均长度为11.5 cm(8-18.5 cm)。至随访结束,患者髋关节Hariss评分从治疗前(39.0±13.6)分提高到治疗后(75.0±14.9)分,差异有显著性意义(P〈0.01)。2例患者发生假体柄下沉,17例患者大转子延长截骨处均固定良好。提示大转子延长截骨结合生物型加长柄翻修人工髋关节过程中,单切口双入路法松解髋关节周围瘢痕并使髋关节前脱位能保护后关节囊和外旋肌,加强髋关节后侧稳定性,减少翻修后脱位率,近期效果满意,长期效果还需进一步观察。

关 键 词:植入物  人工假体  大转子延长截骨  生物型翻修加长柄  翻修  髋关节

Extended trochanteric osteotomy combined with long-stem cementless prosthesis in hip revision
Zhou Wei,Liu Dong-hai,Xu Zhen-wei,Wu Deng-ke,Zhao Shi-yang.Extended trochanteric osteotomy combined with long-stem cementless prosthesis in hip revision[J].Journal of Clinical Rehabilitative Tissue Engineering Research,2014(40):6419-6424.
Authors:Zhou Wei  Liu Dong-hai  Xu Zhen-wei  Wu Deng-ke  Zhao Shi-yang
Institution:(Department of Osteoarthrosis, Pingdingshan First People's Hospital, Pingdingshan 467000, Henan Province, China)
Abstract:BACKGROUND:Extraction of a wel fixed cementless femoral stem or a cemented stem is difficult during revision of total hip arthroplasty. The extended trochanteric osteotomy provides excellent methods, and combining with long-stem cementless prosthesis can better reduce postoperative complications. 〈br〉 OBJECTIVE:To retrospectively analyze the recent clinical curative effect after extended trochanteric osteotomy combined with long-stem cementless prosthesis in hip revision. 〈br〉 METHODA total of 25 patients undergoing hip revision were selected from the Department of Osteoarthrosis, Pingdingshan First People’s Hospital, China from May 2008 to May 2013. Of them, 17 patients were subjected to the extended trochanteric osteotomy combined with single-incision and double-approaches. The femurs were reconstructed with long-stem cementless prosthesis. Al patients were fol owed-up for 12 to 60 months. Pre-operative and post-operative Harris hip scores, the post-operative complications, the bone cutting length, the length of stem in contact with cortical bone, the length of the end of bone cutting to the end of the prosthesis were recorded. 〈br〉 RESULTS AND CONCLUSION:17 patients were fol owed-up. The mean length of bone was 17 cm (15-23 cm). The mean length of stem in contact with cortical bone was 6.4 cm (4-11 cm). The mean length of the end of bone to the end of the prosthesis was 11.5 cm (8-18.5 cm). After fol ow-up, the mean Harris hip scores were improved from (39.0±13.6) scores preoperatively to (75.0±14.9) scores postoperatively (P〈0.01). Subsidence occurred in two hips. The cutting sites of 17 cases of extended trochanteric osteotomy were fixed wel . These data suggested that the operation through single-incision and double-approach to the hip, while preserving the attachment of the external rotators and posterior capsule, wil strength rear hip stability and prevent postoperative dislocations. Recent effects were satisfactory, but the long-term outcomes sho
Keywords:arthroplasty  replacement  hip  bioprosthesis  fol ow-up studies
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号