Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior,reliability and translucency |
| |
Authors: | Amanda Maria de Oliveira Dal Piva João Paulo Mendes Tribst Ernesto Byron Benalcázar Jalkh Lilian Costa Anami Estevam Augusto Bonfante Marco Antonio Bottino |
| |
Affiliation: | 1. PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil;2. Department of Prosthodontics and Periodontology, University of São Paulo – Bauru School of Dentistry. Alameda Dr. Octávio Pinheiro Brisolla, 9-75, 17012-901, Bauru, SP, Brazil |
| |
Abstract: | ObjectiveDespite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns.MethodsDentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia – YZHT, Zirconia reinforced lithium silicate – ZLS and Hybrid ceramic – HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness.ResultsHigher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2).SignificanceHC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation. |
| |
Keywords: | Fatigue Reliability Monolithic crowns Dental materials Tooth wear |
本文献已被 ScienceDirect 等数据库收录! |
|