首页 | 本学科首页   官方微博 | 高级检索  
检索        


First in human experience with an epicardial beating heart device for secondary mitral regurgitation
Authors:Vinod H Thourani  Isaac George  Kestutis Rucinskas  Gintaras Kalinauskas  Vilius Janusauskas  Diana Zakarkaite  Gorav Ailawadi  Robert Smith  Michael J Mack
Institution:1. Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, Ga;2. Division of Cardiothoracic Surgery, New York Presbyterian Hospital-Columbia University Medical Center, New York, NY;3. Vilnius University Clinic of Cardiac and Vascular Diseases, Vilnius, Lithuania;4. Division of Cardiothoracic Surgery, University of Virginia, Charlottesville, Va;5. Baylor Scott & White Heart and Vascular Hospital, Plano, Tex
Abstract:ObjectiveWe describe a novel, off-pump, epicardial implant that is intended to reshape both the mitral valve annulus and the left ventricle (LV) in those with secondary mitral regurgitation (MR).MethodsFive patients underwent an epicardial implant with the Mitral Touch device (Mitre Medical Corp, Morgan Hill, Calif), during concomitant off-pump coronary artery bypass for secondary MR. The median age was 71.2 years; 4 patients had severe MR and 1 moderate. Patients were followed for 1 year with transthoracic echocardiography and computed tomography. Safety, cardiac remodeling, and MR were assessed by an independent core laboratory.ResultsOne patient died within 30 days from nondevice-related organ failure and the remaining 4 survived through 1-year follow-up. Implant technical success was 100% and took an average of 52 minutes. Paired computed tomography showed mean left ventricular end-systolic volume remodeling at 1 and 12 months of ?35% and ?31%, respectively. They averaged left atrial end-systolic volume remodeling of ?12% and ?15% at 1 and 12 months. Right ventricular end-systolic volume changes of ?19% and ?8% and right atrial end-systolic volume remodeling of ?5% and 1%, at the 1- and 12-month time points were noted. Regurgitant volume by transthoracic echocardiography decreased by 46% and 44% and the ejection fraction from 34.6% to 32.1% and 39.5%, at 1 and 12 months, respectively. There were no device-related complications reported to 1 year.ConclusionsThe Epicardial Mitral Touch System for Mitral Regurgitation (ENRAPT-MR) study demonstrates a first-in-man, off-pump, epicardial repair of secondary MR. Procedural safety and geometric correction of the mitral valve apparatus and LV was achieved. Further studies in the United States are underway.
Keywords:mitral regurgitation  mitral repair  mitral valve  beating heart mitral repair  epicardial repair  minimally invasive mitral surgery  AV"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"atrioventricular  CABG"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"coronary artery bypass grafting  CT"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"computed tomography  CTSN"}  {"#name":"keyword"  "$":{"id":"kwrd0075"}  "$$":[{"#name":"text"  "_":"Cardiothoracic Surgical Trials Network  EROA"}  {"#name":"keyword"  "$":{"id":"kwrd0085"}  "$$":[{"#name":"text"  "_":"effective regurgitant orifice area  HF"}  {"#name":"keyword"  "$":{"id":"kwrd0095"}  "$$":[{"#name":"text"  "_":"heart failure  LV"}  {"#name":"keyword"  "$":{"id":"kwrd0105"}  "$$":[{"#name":"text"  "_":"left ventricle  LVEDD"}  {"#name":"keyword"  "$":{"id":"kwrd0115"}  "$$":[{"#name":"text"  "_":"left ventricular end-diastolic diameter  LVEDV"}  {"#name":"keyword"  "$":{"id":"kwrd0125"}  "$$":[{"#name":"text"  "_":"left ventricular end-diastolic volume  LVESV"}  {"#name":"keyword"  "$":{"id":"kwrd0135"}  "$$":[{"#name":"text"  "_":"left ventricular end-systolic volume  MR"}  {"#name":"keyword"  "$":{"id":"kwrd0145"}  "$$":[{"#name":"text"  "_":"mitral regurgitation  MV"}  {"#name":"keyword"  "$":{"id":"kwrd0155"}  "$$":[{"#name":"text"  "_":"mitral valve  SMR"}  {"#name":"keyword"  "$":{"id":"kwrd0165"}  "$$":[{"#name":"text"  "_":"secondary mitral regurgitation  SL"}  {"#name":"keyword"  "$":{"id":"kwrd0175"}  "$$":[{"#name":"text"  "_":"septal-lateral  TEE"}  {"#name":"keyword"  "$":{"id":"kwrd0185"}  "$$":[{"#name":"text"  "_":"transesophageal echocardiography  TTE"}  {"#name":"keyword"  "$":{"id":"kwrd0195"}  "$$":[{"#name":"text"  "_":"transthoracic echocardiography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号