首页 | 本学科首页   官方微博 | 高级检索  
检索        


Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional,bulk-fill and short-fibre reinforced resin composites
Authors:Edina Lempel  Zsuzsanna Őri  Dóra Kincses  Bálint Viktor Lovász  Sándor Kunsági-Máté  József Szalma
Institution:1. Department of Restorative Dentistry and Periodontology, University of Pécs, 5 Dischka Gy?z? Street, Pécs H-7621, Hungary;2. Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs H-7624, Hungary;3. János Szentágothai Research Center, 20 Ifjúság Street, Pécs H-7624, Hungary;4. University of Pécs Medical School, 12 Szigeti Street, Pécs H-7624, Hungary;5. Faculty of Pharmacy, Institute of Organic and Medicinal Chemistry, University of Pécs, 12 Szigeti Street, Pécs H-7624, Hungary;6. Department of Oral and Maxillofacial Surgery, University of Pécs, 5 Dischka Gy?z? Street, Pécs H-7621, Hungary
Abstract:ObjectiveDetermine the degree of conversion (DC) and in vitro pulpal temperature (PT) rise of low-viscosity (LV) and high-viscosity (HV) conventional resin-based composites (RBC), bulk-fill and short-fibre reinforced composites (SFRC).MethodsThe occlusal surface of a mandibular molar was removed to obtain dentine thickness of 2 mm above the roof of the pulp chamber. LV and HV conventional (2 mm), bulk-fill RBCs (2–4 mm) and SFRCs (2–4 mm) were applied in a mold (6 mm inner diameter) placed on the occlusal surface. PT changes during the photo-polymerization were recorded with a thermocouple positioned in the pulp chamber. The DC at the top and bottom of the samples was measured with micro-Raman spectroscopy. ANOVA and Tukey’s post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05).ResultsThe PT changes ranged between 5.5–11.2 °C. All LV and 4 mm RBCs exhibited higher temperature changes. Higher DC were measured at the top (63–76%) of the samples as compared to the bottom (52–72.6%) in the 2 mm HV conventional and bulk-fill RBCs and in each 4 mm LV and HV materials. The SFRCs showed higher temperature changes and DC% as compared to the other investigated RBCs. The temperature and DC were influenced by the composition of the material followed by the thickness.SignificanceExothermic temperature rise and DC are mainly material dependent. Higher DC values are associated with a significant increase in PT. LV RBCs, 4 mm bulk-fills and SFRCs exhibited higher PTs. Bulk-fills and SFRCs applied in 4 mm showed lower DCs at the bottom.
Keywords:Pulpal temperature  Degree of conversion  Resin composite  Bulk-fill  Fiber-reinforced
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号