首页 | 本学科首页   官方微博 | 高级检索  
     

虹膜定位波前像差引导的LASIK治疗近视散光术后视觉质量的研究
引用本文:郭 宁,周跃华,张丰菊,张 晶. 虹膜定位波前像差引导的LASIK治疗近视散光术后视觉质量的研究[J]. 大连医科大学学报, 2009, 31(6): 675-678
作者姓名:郭 宁  周跃华  张丰菊  张 晶
作者单位:首都医科大学,附属北京同仁医院,眼科,北京同仁眼科中心,北京市眼科学与视觉科学重点实验室,北京,100730;首都医科大学,附属北京同仁医院,眼科,北京同仁眼科中心,北京市眼科学与视觉科学重点实验室,北京,100730;首都医科大学,附属北京同仁医院,眼科,北京同仁眼科中心,北京市眼科学与视觉科学重点实验室,北京,100730;首都医科大学,附属北京同仁医院,眼科,北京同仁眼科中心,北京市眼科学与视觉科学重点实验室,北京,100730
摘    要:[目的]评估虹膜定位联合波前像差引导的LASIK治疗近视散光的临床疗效及视觉质量。[方法]选取柱镜≥-1.0D的近视散光患者随机分为两组,分别接受虹膜定位联合波前像差引导的LASIK(82例,130眼)和常规LASIK(77例,118眼)治疗,比较术后3月、6月及1年裸眼视力、残余散光度、高阶像差和对比敏感度。[结果]术后各时期,虹膜定位组裸眼视力均优于常规组(P〈0.05);虹膜定位组残余散光度均低于常规组(P〈0.05);虹膜定位组高阶像差各项均低于常规组,其中术后3月两组RMSh、Coma及RMS6差异有统计学意义(P〈0.05),术后6月两组RMSh、Coma、Trefoil、RMS3及RMS6差异有统计学意义(P〈0.05),术后1年两组RMSh、Coma及RMS3差异有统计学意义(P〈0.05)。术后1年,虹膜定位组(除Trefoil)和常规组高阶像差各项均较术前明显增加(P〈0.05)。术后1年,虹膜定位组对比敏感度在暗光及暗光+眩光状态下所有频段均明显好于常规组(P〈0.05)。[结论]虹膜定位联合波前像差引导的LASIK能有效治疗近视散光,提高术后视觉质量。

关 键 词:准分子激光原位角膜磨镶术  散光  像差  对比敏感度

Visual performance of Wavefront-guided LASIK with Iris-registration for myopic astigmatism
GUO Ning,ZHOU Yue-hu,ZHANG Feng-ju and ZHANG Jing. Visual performance of Wavefront-guided LASIK with Iris-registration for myopic astigmatism[J]. Journal of Dalian Medical University, 2009, 31(6): 675-678
Authors:GUO Ning  ZHOU Yue-hu  ZHANG Feng-ju  ZHANG Jing
Affiliation:GUO Ning,ZHOU Yue-hua,ZHANG Feng-ju,ZHANG Jing(Beijing Tongren Hospital,Capital Medical University,Beijing 100730,China)
Abstract:[Objective] To evaluate the visual performance and outcome of wavefront-guided Laser in situ keratomileusis(LASIK) with iris-registration for myopic astigmatism.[Methods] Patients with myopic astigmatism(≥1.0D,Cylindric lens) were randomly divided into two groups: the wavefront-guided LASIK with iris-registration group(82 patients,130 eyes,experimental group) and conventional LASIK group(77 patients,118 eyes).Uncorrected visual acuity(UCVA),residual astigmatism,the higher order aberrations and contrast sensitivity(CS) were compared at 3,6 and 12 month postoperatively.[Results] At 3,6 and 12 month after operation,the UCVA of experimental group was better than that of the conventional group;residual astigmatism of experimental group was smaller than that of conventional group;the higher order aberrations of experimental group were smaller than that of conventional group(all P<0.05).At 3 month post-operation,the RMSh,Coma and RMS6 were significantly difference(P<0.05) between the two groups.At 6 month post-operation,the RMSh,Coma,Trefoil,RMS3 and RMS6 of the two groups were significantly difference(P<0.05).At twelve month post-operation,the RMSh,Coma and RMS3 of the two groups were significant difference(P<0.05).The experimental group showed better CS values at all spatial frequencies than that of conventional group with and without glare at 12 month post-operation(P<0.05).[Conclusion] Wavefront-guided LASIK with iris-registration is more effective for myopic astigmatism with better visual performance.
Keywords:laser in situ keratomileusis  astigmatism  aberration  contrast sensitivity  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《大连医科大学学报》浏览原始摘要信息
点击此处可从《大连医科大学学报》下载免费的PDF全文