A novel repair method for the treatment of acute Achilles tendon rupture with minimally invasive approach using button implant: A biomechanical study |
| |
Authors: | Gazi Huri Ömer Sunkar Biçer Levent Özgözen Yurdanur Uçar Nickolas G. Garbis Yoon Suk Hyun |
| |
Affiliation: | 1. Department of Orthopaedic and Traumatology Surgery, Cukurova University, Adana, Turkey;2. Department of Orthopaedics and Traumatology Surgery, Division of Sport Medicine, Johns Hopkins University, Baltimore, MD, USA;3. Department of Prosthetic Dentistry, College of Dentistry, Cukurova University, Balcali, Adana, Turkey;4. Department of Orthopaedic and Traumatology Surgery, Hallym University, Chuncheon, Republic of Korea |
| |
Abstract: | BackgroundMinimally invasive Q3 repair has been proposed for acute Achilles tendon rupture with low rate of complications. However there are still controversies about optimal technique. In this study we aimed to describe Endobutton-assisted modified Bunnell configuration as a new Achilles tendon repair technique and evaluate its biomechanical properties comparing with native tendon and Krackow technique.Methods27 ovine Achilles tendons were obtained and randomly placed into 3 groups with 9 specimens ineach. The Achilles tendons were repaired with Endobutton-assisted modified Bunnell technique in group 1, Krackow suture technique in group 2 and group 3 was defined as the control group including native tendons. Unidirectional tensile loading to failure was performed at 25 mm/min. Biomechanicalproperties such as peak force to failure (N), stress at peak (MPa), elongation at failure, and Young'smodulus (GPa) was measured for each group. All groups were compared with each other using one-wayANOVA followed by the Tukey HSD multiple comparison test (a = 0.05).ResultsThe average peak force (N) to failure of group 1 and group 2 and control group was 415.6 ± 57.6, 268.1 ± 65.2 and 704.5 ± 85.8, respectively. There was no statistically significant difference between native tendon and group 1 for the amount elongation at failure (p > 0.05).ConclusionsRegarding the results, we concluded that Endobutton-assisted modified Bunnell technique provides stronger fixation than conventional techniques. It may allow early range of motion and can be easily applied in minimally invasive and percutaneous methods particularly for cases with poor quality tendon at the distal part of rupture.Level of evidenceLevel II, Biomechanical research study. |
| |
Keywords: | Endobutton Achilles tendon Acute Rupture Repair Minimally invasive |
本文献已被 ScienceDirect 等数据库收录! |
|