首页 | 本学科首页   官方微博 | 高级检索  
     


Reduce in variation and improve efficiency of target volume delineation by a computer-assisted system using a deformable image registration approach
Authors:Chao K S Clifford  Bhide Shreerang  Chen Hansen  Asper Joshua  Bush Steven  Franklin Gregg  Kavadi Vivek  Liengswangwong Vichaivood  Gordon William  Raben Adam  Strasser Jon  Koprowski Christopher  Frank Steven  Chronowski Gregory  Ahamad Anesa  Malyapa Robert  Zhang Lifei  Dong Lei
Affiliation:Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX 7030, USA. cchao@mdanderson.org
Abstract:PURPOSE: To determine whether a computer-assisted target volume delineation (CAT) system using a deformable image registration approach can reduce the variation of target delineation among physicians with different head and neck (HN) IMRT experiences and reduce the time spent on the contouring process. MATERIALS AND METHODS: We developed a deformable image registration method for mapping contours from a template case to a patient case with a similar tumor manifestation but different body configuration. Eight radiation oncologists with varying levels of clinical experience in HN IMRT performed target delineation on two HN cases, one with base-of-tongue (BOT) cancer and another with nasopharyngeal cancer (NPC), by first contouring from scratch and then by modifying the contours deformed by the CAT system. The gross target volumes were provided. Regions of interest for comparison included the clinical target volumes (CTVs) and normal organs. The volumetric and geometric variation of these regions of interest and the time spent on contouring were analyzed. RESULTS: We found that the variation in delineating CTVs from scratch among the physicians was significant, and that using the CAT system reduced volumetric variation and improved geometric consistency in both BOT and NPC cases. The average timesaving when using the CAT system was 26% to 29% for more experienced physicians and 38% to 47% for the less experienced ones. CONCLUSIONS: A computer-assisted target volume delineation approach, using a deformable image-registration method with template contours, was able to reduce the variation among physicians with different experiences in HN IMRT while saving contouring time.
Keywords:Target delineation   Deformable image registration   Contour variations   Auto-segmentation   Computer-assisted
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏