Pulmonary clearance of 99mTc-HMPAO aerosol |
| |
Authors: | K Kawakami S Tominaga H Takagi Y Mori E Gotou A Iwamura T Shimada |
| |
Institution: | Department of Radiology, Jike University School of Medicine, Tokyo, Japan. |
| |
Abstract: | The clearance rate of inhaled aerosols of a lipophilic substance, 99mTc-HMPAO (Hexamethyl propylene amine oxime) was studied and compared to that of hydrophilic substances in 6 normal volunteers and 18 patients with lung diseases. The subject in sitting position inhaled a single deep breath of 99mTc-HMPAO aerosols, and held his breath about 30 sec. Then he continued to breath aerosols again for about 3 min. Radioactivity rapidly falls down during breath holding, to about 60% of the peak value (fast phase), with T 1/2 of 3.75 +/- 2.22 sec in 6 normal volunteers. This rapid phase was not appeared in hydrophilic aerosols with 99mTc-DTPA and 99mTc-pertechnetate and in lipophilic aerosol with 123I-IMP aerosol. The clearance of residual activity of 99mTc-HMPAO was slow with T 1/2 of 17.4 +/- 4.0 min. The T 1/2 of 99mTc-DTPA, 99mTc-pertechnetate and 123I-IMP were 50.2 +/- 20.9 min, 11.4 +/- 4.3, and 62.5 +/- 20.8 min respectively. 99mTc-HMPAO may cross transcellularly using the whole alveolar surface. The clearance of aerosols in the fast phase is rapid and depend on the regional perfusion. On the other hand, hydrophilic aerosol pass by an intercellular pathway and the clearance will be diffusion limited. As conclusion, inhalation study of 99mTc-HMPAO might be a new method to evaluate perfusion following ventilation study. |
| |
Keywords: | |
|
|