桡动脉止血装置在经桡动脉冠状动脉造影术后应用的临床研究
引用本文:周波,张伟,颜玮如,黄巍巍,唐小山.桡动脉止血装置在经桡动脉冠状动脉造影术后应用的临床研究[J].华夏医学,2007,20(2):185-187.
作者姓名:周波  张伟  颜玮如  黄巍巍  唐小山
作者单位:桂林市人民医院外事干部病房,广西,桂林,541002;桂林市人民医院心血管科,广西,桂林,541002
摘    要:目的:探讨桡动脉止血装置TR Band(日本Terumo公司生产)在经桡动脉径路行冠状动脉造影术后应用的安全性及有效性。方法:选取Allen试验阳性并经桡动脉径路行冠状动脉造影的40例患者,随机将患者分为两组:TR Band组(20例),“8”字绷带包扎组(20例),于冠状动脉造影术后,分别用桡动脉止血装置TR Band及弹力绷带“8”字包扎止血,比较两种方法的止血效果、止血耗时、患者舒适度、静脉回流情况、压迫侧大拇指血氧饱和度、压迫侧手部、前臂肿胀、青淤现象。结果:TR Band组与“8”字绷带包扎组比较,在止血效果、压迫侧大拇指血氧饱和度方面无统计学差异(P〉0.05),而在止血时间、患者舒适度上TR Band组优于“8”字绷带包扎组(P〈0.05),静脉回流障碍、压迫侧手部、前臂肿胀、青淤现象少于“8”字绷带包扎组(P〈0.05)。结论:经桡动脉径路行冠状动脉造影,术后应用桡动脉止血装置TR Band安全、有效。

关 键 词:桡动脉止血装置  桡动脉  冠状动脉造影
文章编号:1008-2409(2007)02-0185-03
修稿时间:2007年1月17日

The clinical research about radial artery hemostasis device after transradial coronary arteriography
ZHOU Bo,ZHANG Wei,YAN Wei-ru,et al..The clinical research about radial artery hemostasis device after transradial coronary arteriography[J].Acta Medicinae Sinica,2007,20(2):185-187.
Authors:ZHOU Bo  ZHANG Wei  YAN Wei-ru  
Institution:ZHOU Bo,ZHANG Wei,YAN Wei-ru,et al.The People's Hospital of Guilin City,Guilin 541002,China
Abstract:Objective: To evaluate the safety and effect of applement radial artery hemostasis device"TR Band"after transradial coronary arteriography.Methods: 40 patients with Allen test positive who accepted transradial coronary arteriography were divided into two groups: TR Band group(20 cases) and "8"type bandaging group(20 cases).Stop bleeding respectively using radial artery hemostasis device"TR Band" or "8" type bandaging after transradial coronary arteriography.Hemostasis effect,hemostasis consuption time,patients comfortable degree,venous return condition,blood oxygen saturation on oppressed thumb,swelling and bruise on oppressed forearm and palm of hand were compared in the two groups.Results: hemostasis effect,blood oxygen saturation on oppressed thumb had no difference between the two groups(P>0.05),but,hemostasis consumption time,patients comfortable degree were better in TR Band group than in "8" type bandaging group(P<0.05).The venous return obstruction,swelling and bruise on oppressed forearm and palm of hand were less in TR Band group than in "8" type bandaging group(P<0.05).Conclusion: The applement of radial artery hemostasis device after transradial coronary arteriography is safe and effective.
Keywords:radial artery hemostasis device  radial artery  coronary arteriography