Use of Oversized Injectable Valves in Growing Children for Total Repair of Right Ventricular Outflow Tract Anomalies (Preliminary Results)
Authors:Luca Deorsola  Pietro Angelo Abbruzzese
Affiliation:Pediatric Cardiac Surgery Division, Regina Margherita Hospital, 10126 Turin, Italy
Abstract:Right ventricular outflow tract surgery was originally confined to transannular patching, in the belief that pulmonary regurgitation was well tolerated. Because follow-up evaluations revealed the deleterious effects of pulmonary regurgitation, surgery today aims to spare or replace the valve. Available replacement devices have short lifetimes, considering growth mismatch in children. We hypothesize that oversizing the right infundibulum anticipates growth and that a squeezed prosthesis can complete the expansion process.The No-React® Injectable BioPulmonic Valve is designed for right infundibular surgery in adults, and hundreds of implants have shown promising results. We used this device for surgery in babies, with the addition of an innovative oversizing technique. This study evaluates our preliminary results and investigates whether such a technique might reduce growth mismatch.From September 2010 through July 2012, we implanted 11 injectable pulmonic valves. The median age of our patients was 23 months. After opening the right infundibulum, we enlarged it as much as possible with a wide patch. Before completing the patch suture, we injected an oversized valve.No problems occurred during surgery. No major insufficiency or leak was observed. We conclude that prostheses can be quite oversized and perform well even when not completely expanded.Oversized injectable pulmonic valves, shrunken to a smaller diameter, enabled the implantation of a device wider than otherwise possible, without affecting performance. Moreover, the prosthesis tended to return to its original size following growth, thereby reducing growth mismatch. Longer follow-up and larger numbers of patients are needed for verification.
Keywords:Bioprosthesis   cardiac surgical procedures/methods/pediatric   child   constriction   pathologic   heart defects   congenital   heart valve prosthesis implantation   infant   prostheses and implants   pulmonary regurgitation   pulmonary valve/abnormalities/surgery   pulmonary valve insufficiency   right ventricular outflow tract   time factors   treatment outcome   ventricular outflow obstructions
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号