首页 | 本学科首页   官方微博 | 高级检索  
检索        


Preoperative lymph node staging in patients with primary prostate cancer: comparison and correlation of quantitative imaging parameters in diffusion-weighted imaging and 11C-choline PET/CT
Authors:Tibor Vag  Matthias M Heck  Ambros J Beer  Michael Souvatzoglou  Gregor Weirich  Konstantin Holzapfel  Bernd Joachim Krause  Markus Schwaiger  Matthias Eiber  Ernst J Rummeny
Institution:1. Clinic of Nuclear Medicine, Klinikum Rechts der Isar, Technical University Munich, Ismaninger Strasse 22, 81675, Munich, Germany
2. Clinic of Urology, Klinikum Rechts der Isar, Technical University Munich, Ismaninger Strasse 22, 81675, Munich, Germany
3. Institute of Pathology, Klinikum Rechts der Isar, Technical University Munich, Trogerstrasse 18, 81675, Munich, Germany
4. Institute of Diagnostic and Interventional Radiology, Klinikum Rechts der Isar, Technical University Munich, Ismaninger Strasse 22, 81675, Munich, Germany
5. Clinic of Nuclear Medicine, University Hospital Rostock, Getrudenplatz 1, 18057, Rostock, Germany
Abstract:

Purpose

To compare the diagnostic performance of DWI and 11C-choline PET/CT in the assessment of preoperative lymph node status in patients with primary prostate cancer.

Material and methods

Thirty-three patients underwent DWI and 11C-choline PET/CT prior to prostatectomy and extended pelvic lymph node dissection. Mean standardised uptake value (SUVmean) and mean apparent diffusion coefficient (ADC) of 76 identified lymph nodes (LN) were measured and correlated with histopathology. ADC values and SUVs were compared using linear regression analysis.

Results

A significant difference between benign and malignant LN was observed for ADC values (1.17 vs. 0.96?×?10-3 mm2/s; P?<?0.001) and SUVmean (1.61 vs. 3.20; P?<?0.001). ROC analysis revealed an optimal ADC threshold of 1.01?×?10-3 mm2/s for differentiating benign from malignant LN with corresponding sensitivity/specificity of 69.70 %/78.57 % and an area under the curve (AUC) of 0.785. The optimal threshold for SUVmean was 2.5 with corresponding sensitivity/specificity of 69.72 %/90.48 % and with an AUC of 0.832. ADC values and SUVmean showed a moderate significant inverse correlation (r?=?-0.63).

Conclusion

Both modalities reveal similar moderate diagnostic performance for preoperative lymph node staging of prostate cancer, not justifying their application in routine clinical practice at this time. The only moderate inverse correlation between ADC values and SUVmean suggests that both imaging parameters might provide complementary information on tumour biology.

Key Points

? Conventional imaging shows low performance for lymph node staging in prostate cancer. ? DWI and 11C-choline PET/CT both provide additional functional information ? Both functional modalities reveal only moderate diagnostic performance.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号