颈椎前路钮扣钢板的研制及生物力学评价
引用本文:曹盛俊,梁秋发,王文军,赵卫东,黄文华,李鉴轶.颈椎前路钮扣钢板的研制及生物力学评价[J].中国临床解剖学杂志,2003,21(2):176-179.
作者姓名:曹盛俊  梁秋发  王文军  赵卫东  黄文华  李鉴轶
作者单位:1. 南华大学附属第一医院骨科,,湖南,衡阳,421001
2. 第一军医大学全军医学生物力学重点实验室,广东,广州,510515
摘    要:目的:研制颈椎前路钮扣钢板内固定系统,评价其生物力学稳定性。方法:用317L不锈钢研制出颈椎前路钮扣钢板螺钉系统。取6具青年男性新鲜尸体的颈椎标本,制成5种状态脊柱功能单位(FSU)的试验模型:正常颈椎、屈曲型损伤、单纯植骨、钮扣钢板内固定、AO钢板内固定。利用脊柱三维运动分析系统测定不同状态下颈椎节段的运动范围(ROM),比较钮扣钢板内固定与AO钢板内固定对失稳颈椎的稳定作用,并摄X线片观察各种状态下颈椎的影像学改变。结果:生物力学测试表明,钮扣钢板内固定系统可以对失稳颈椎提供明显的稳定作用(P<0.01),与AO钢板内固定系统的稳定作用相比无显著性差异(P>0.05)。动态X线摄片显示,钮扣钢板内固定及AO钢板内固定均能维持植骨块的稳定,并恢复椎间隙高度及颈椎生理曲度,而单纯植骨则容易出现植骨块的移位、凸出甚至脱出。结论:钮扣钢板内固定系统具有较好的生物力学稳定性。操作简便,适合国人颈椎解剖结构及功能特点。

关 键 词:颈椎  钮扣钢板  生物力学
文章编号:1001-165X(2003)02-0176-04
修稿时间:2002年1月16日

Design and biomechanical evaluation of anterior cervical button plate fixation system
CAO Sheng-jun,LIANG Qiu-fa,WANG Wen-jun,et al..Design and biomechanical evaluation of anterior cervical button plate fixation system[J].Chinese Journal of Clinical Anatomy,2003,21(2):176-179.
Authors:CAO Sheng-jun  LIANG Qiu-fa  WANG Wen-jun  
Institution:CAO Sheng-jun,LIANG Qiu-fa,WANG Wen-jun,et al. Department of Orthopaedics,the First Affiliated Hospital of Nanhua University,Hengyang 421001,China
Abstract:Objective: To evaluate the biomechanical stability of self-designed anterior button-like buttressing plate fixation system. Methods: The anterior button-like buttressing plate fixation system was designed with 317L steel . Six fresh cervical spine specimens (C1-T1 ) from young male cadavers were used to establish normal contrast, flexion injury, ilial crest strut graft, button-like plate internal fixation, and AO plate fixation models. Biomechanical stability analyses were performed by testing cervical vertebral range of motion (ROM) in sequence . The dynamic radiographs were taken to observe the cervical alignment in different conditions. Results: The anterior cervical button-like plate system decreased significantly the ROM in unstable cervical spine models (P<0. 01) . The dynamic radiographs showed that both button-like plate and AO plate can augment the stability of graft constructions, but migration and dislodgement would be seen on the grafts without plate fixation . Conclusion: The anterior cervical button-like buttressing plate fixation system can provide sufficient biomechanical stability in cervical spine after anterior decompression-bone graft fusion.
Keywords:cervical spine  button plate  biomechanics
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号