首页 | 本学科首页   官方微博 | 高级检索  
检索        

EnSite NavX三维电生理系统指导下环肺静脉前庭隔离导管消融治疗心房颤动
引用本文:谭海斌,杨希立,温旭涛.EnSite NavX三维电生理系统指导下环肺静脉前庭隔离导管消融治疗心房颤动[J].南方医科大学学报,2008,28(7):1273-1275.
作者姓名:谭海斌  杨希立  温旭涛
作者单位:佛山市第一人民医院心内科,广东,佛山,528000
摘    要:目的 探讨EnSire NavX三维电生理系统指导环肺静脉前庭隔离导管消融治疗心房颤动(房颤)的有效性和安全性.方法 在EnSite NavX三维电生理系统指导下对38例药物治疗无效的阵发性或持续性房颤患者行环肺静脉导管消融,随访观察其疗效和安全性.结果 38例患者都达到消融终点,双侧肺静脉均完全隔离.手术操作时间(233.8±31.7)min,X线曝光时间(32.5±4.7)min,左房建模时间(27.5±7.5)min.术后随访(9±3)月,单次消融的成功率为89.5%,出现并发症7.9%.结论 EnSite NavX三维电生理系统指导下环肺静脉前庭隔离导管捎融治疗房颤是一种较为有效且安全的方法.

关 键 词:心房颤动  导管消融  三维电标测系统  环肺静脉前庭  三维  电生理系统  指导  肺静脉  完全隔离  导管消融治疗  心房颤动  mapping  electrophysiological  atrial  fibrillation  isolation  疗效和安全性  治疗房颤  并发症  成功率  术后随访  曝光时间  建模  左房  手术操作时间

Circumferential pulmonary vein ostial isolation for atrial fibrillation guided by EnSite NavX three-dimensional electrophysiological mapping
TAN Hai-bin,YAN Xi-li,WEN Xu-tao.Circumferential pulmonary vein ostial isolation for atrial fibrillation guided by EnSite NavX three-dimensional electrophysiological mapping[J].Journal of Southern Medical University,2008,28(7):1273-1275.
Authors:TAN Hai-bin  YAN Xi-li  WEN Xu-tao
Institution:Department of Cardiology, Foshan First People's Hospital, Foshan 528000, China. E-mail:fsthbi@sina.com.cn.
Abstract:OBJECTIVE: To investigate the efficacy and safety of circumferential pulmonary vein ostial isolation guided by EnSite NavX three-dimensional electrophysiological mapping in patients with atrial fibrillation (AF). METHODS: Thirty-eight patients with drug refractory paroxysmal or persistent AF underwent circumferential pulmonary vein ostial isolation and were followed up to investigate the efficacy and safety of the treatment. RESULTS: All cases reached the endpoint of the ablation, and both sides of the pulmonary vein were completely isolated, with an average procedure time of 200.4-/+37.0 min, X-ray exposure time of 54.7-/+9.7 min, and three-dimensional left atrial geometry reconstruction time of 27.5-/+7.5 min. During the follow-up for 9-/+3 months, the success rate of initial ablation was 89.5%, and the incidence of procedure-related complications were 7.9%. CONCLUSIONS: Circumferential pulmonary vein ostial isolation guided by EnSite NavX three-dimensional electrophysiological mapping can be effective and safe for AF treatment.
Keywords:atrial fibrillation  radiofrequency catheter ablation  three-dimensional electrophysiological mapping  circumferential pulmonary vein ostia  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号