首页 | 本学科首页   官方微博 | 高级检索  
     

三维扫描重建女性生殖系统模型在胚胎移植培训中的应用
引用本文:饶金鹏,邱枫,蔡益婷,魏凯,金敏,金帆. 三维扫描重建女性生殖系统模型在胚胎移植培训中的应用[J]. 基础医学与临床, 2020, 40(3): 411-414. DOI: 10.3969/j.issn.1001-6325.2020.03.032
作者姓名:饶金鹏  邱枫  蔡益婷  魏凯  金敏  金帆
作者单位:浙江大学医学院 附属第二医院生殖医学中心,浙江 杭州,310000;浙江大学医学院 附属妇产科医院, 生殖遗传教育部重点实验室,浙江 杭州310000
基金项目:国家自然科学基金;浙江省医药卫生科技计划
摘    要:目的探讨三维扫描重建技术在胚胎移植培训中的效果。方法用三维扫描仪、数据处理软件EXScan-Pro、3D打印机重建出标准及子宫颈内口狭窄两套女性生殖系统模型。对20位临床及实验室人员进行废弃胚胎的模拟移植培训教学,并对培训前后胚胎种植部位准确性、胚胎移植操作时间以及更换移植导管的频次进行统计和评价。结果胚胎种植部位准确性得分由(0. 60±0. 41)分提高至(1. 37±0. 29)分(P<0. 05);胚胎移植操作时间由(340±146) s缩短至(180±59) s(P<0. 05);更换移植导管的频次由(0. 83±0. 37)次下降(0. 23±0. 13)次(P<0. 05)。结论三维扫描重建女性生殖系统模型应用于胚胎移植教学培训,能有效增加操作者正式上台手术前的实践经验,提高胚胎移植技术实施的稳定性,也有利于建立规范的操作流程,是传统观摩和带教方法的有益补充。

关 键 词:生殖系统  胚胎移植  三维扫描  三维打印  培训教学

Application of three-dimensional scanning in rebuilding female reproductive system model for embryo transfer training
RAO Jin-peng,QIU Feng,CAI Yi-ting,WEI Kai,JIN Min,JIN Fan. Application of three-dimensional scanning in rebuilding female reproductive system model for embryo transfer training[J]. Basic Medical Sciences and Clinics, 2020, 40(3): 411-414. DOI: 10.3969/j.issn.1001-6325.2020.03.032
Authors:RAO Jin-peng  QIU Feng  CAI Yi-ting  WEI Kai  JIN Min  JIN Fan
Affiliation:(Reproductive Medical Center,the Second Affiliated Hospital;Key Laboratory of Reproductive Genetics of Ministry of Education,Women's Hospital,School of Medicine of Zhejiang University,Hangzhou 310000,China)
Abstract:Objective To explore three-dimensional scanning and reconstruction technology in embryo transfer training. Methods Two sets of female reproductive system models,standard and cervical stenosis,were reconstructed with three-dimensional scanner,data processing software EXScan-Pro and 3D printer. Twenty clinical and laboratory personnel were trained to simulate the transfer of degenerated embryos,and the accuracy of embryo implantation site,the time required for embryo transfer and the frequency of replacing the transfer catheter before and after the training were evaluated. Results After training,the accuracy score of embryo implantation site was increased from 0. 60±0. 41 to 1. 37±0. 29( P<0. 05);the time required for embryo transfer was shortened from( 340±146) s to( 180±59) s( P < 0. 05);the frequency of replacing the transfer catheter was decreased from( 0. 83 ±0. 37) to( 0. 23 ± 0. 13) times( P < 0. 05). Conclusions Application of rebuilding female reproductive system model for embryo transfer training can improve the practical experience of operators prior to formal surgery,improve the stability of embryo transfer and help to establish a standardized operation process,as a supplement to the traditional observation and teaching methods.
Keywords:reproductive system  embryo transplantation  3D scanning  3D printing  training
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号