Evaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures
Authors:Ling Thomas K W  Liu Z K  Cheng Augustine F B
Affiliation:Department of Microbiology, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, Special Administrative Region, People's Republic of China. lingt@cuhk.edu.hk
Abstract:This study explores the possibility of combining the BacT/Alert Microbial Detection System with the VITEK 2 system to achieve rapid bacterial identification and susceptibility testing. Direct inoculation of bacterial suspension to the VITEK 2 ID-GNB card and AST-NO09 card was made by differential centrifugation of blood cultures of organisms with gram-negative enteric bacillus-like morphology. A total of 118 strains were investigated; of these, 97 (82.2%) strains were correctly identified to the species level and 21 (17.8%) strains were not identified; by comparing the results with those of the reference method of API identification systems using a pure culture, it was found that no strain had been misidentified. Among the 21 strains with no identification, 13 (61.9%) strains were nonfermenters. The direct-identification reporting time of VITEK 2 was 3.3 h. Direct testing of susceptibility to 11 antibiotics, i.e., amikacin, cefepime, ceftazidime, ciprofloxacin, gentamicin, imipenem, meropenem, netilmicin, piperacillin, piperacillin-tazobactam, and tobramycin, was also performed by using the broth microdilution (MB) method according to the NCCLS guidelines as a reference. After comparing the MICs of the VITEK 2 system with those obtained by the MB method within +/-twofold dilution, it was determined that the 1,067 organism-antibiotic combinations had an overall correct rate of 97.6% (1,041 combinations). The rates of susceptibility to the 11 antibiotics ranged from 88.7 to 100%, respectively. Only two (0.2%) and four (0.4%) combinations of the susceptibility tests gave very major errors (i.e., reported as sensitive by the VITEK 2 system but shown to be resistant by the MB method) and major errors (i.e., reported as resistant by the VITEK 2 system but shown to be sensitive by the MB method), respectively. The reporting time for the direct testing of susceptibility against the 11 antibiotics for 97 blood culture isolates by the VITEK 2 system ranged from 3.3 to 17.5 h. Compared with conventional methods that require 1 or 2 days, this method can make same-day reporting possible and thus permit better patient management.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号