首页 | 本学科首页   官方微博 | 高级检索  
     


The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations
Authors:Tzedakis A  Damilakis J  Perisinakis K  Stratakis J  Gourtsoyiannis N
Affiliation:Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 1393, 71409 Iraklion, Crete, Greece.
Abstract:z overscanning in multidetector (MD) helical CT scanning is prerequisite for the interpolation of acquired data required during image reconstruction and refers to the exposure of tissues beyond the boundaries of the volume to be imaged. The aim of the present study was to evaluate the effect of z overscanning on the patient effective dose from helical MD CT examinations. The Monte Carlo N-particle radiation transport code was employed in the current study to simulate CT exposure. The validity of the Monte Carlo simulation was verified by (a) a comparison of calculated and measured standard computed tomography dose index (CTDI) dosimetric data, and (b) a comparison of calculated and measured dose profiles along the z axis. CTDI was measured using a pencil ionization chamber and head and body CT phantoms. Dose profiles along the z axis were obtained using thermoluminescence dosimeters. A commercially available mathematical anthropomorphic phantom was used for the estimation of effective doses from four standard CT examinations, i.e., head and neck, chest, abdomen and pelvis, and trunk studies. Data for both axial and helical modes of operation were obtained. In the helical mode, z overscanning was taken into account. The calculated effective dose from a CT exposure was normalized to CTDI(free in air). The percentage differences in the normalized effective dose between contiguous axial and helical scans with pitch = 1, may reach 13.1%, 35.8%, 29.0%, and 21.5%, for head and neck, chest, abdomen and pelvis, and trunk studies, respectively. Given that the same kilovoltage and tube load per rotation were used in both axial and helical scans, the above differences may be attributed to z overscanning. For helical scans with pitch = 1, broader beam collimation is associated with increased z overscanning and consequently higher normalized effective dose value, when other scanning parameters are held constant. For a given beam collimation, the selection of a higher value of reconstructed image slice width increases the normalized effective dose. In conclusion, z overscanning may significantly affect the patient effective dose from CT examinations performed on MD CT scanners. Therefore, an estimation of the patient effective dose from MD helical CT examinations should always take into consideration the effect of z overscanning.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号