首页 | 本学科首页   官方微博 | 高级检索  
检索        


Accuracy of Two Malaria Rapid Diagnostic Tests (RDTS) for Initial Diagnosis and Treatment Monitoring in a High Transmission Setting in Uganda
Authors:Phoebe Mbabazi  Heidi Hopkins  Emmanuel Osilo  Michael Kalungu  Pauline Byakika-Kibwika  Moses R Kamya
Institution:Department of Medicine, Makerere University College of Health Sciences, Kampala, Uganda; Foundation for Innovative New Diagnostics (FIND), Kampala, Uganda; Infectious Diseases Research Collaboration, Kampala, Uganda; Infectious Diseases Institute, Kampala, Uganda
Abstract:Malaria rapid diagnostic tests (RDTs) may improve fever management in areas without microscopy. We compared the accuracy of histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (pLDH)-based RDTs, using expert microscopy as a gold standard, for initial diagnosis, treatment monitoring, and diagnosis of recurrent malaria in a cohort of children followed longitudinally in a high-transmission area in Uganda. For 305 initial fever episodes, sensitivity was 98% for HRP2 and 87% for pLDH, whereas specificity was 55% and 96%, respectively. The HRP2 gave 51% false-positive results on Day 28, whereas pLDH gave no false positives after Day 7. For 59 recurrent fever episodes during follow-up, sensitivity was 100% for HRP2 and 91% for pLDH, whereas specificity was 33% and 100%, respectively. The HRP2-based RDTs are useful for initial diagnosis of malaria caused by superior sensitivity; however, as a result of superior specificity, pLDH-based RDTs are more appropriate to monitor treatment and diagnose recurrent malaria.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏