首页 | 本学科首页   官方微博 | 高级检索  
     

便携式输注泵输注不同剂型5-氟尿嘧啶临床应用时间差异分析
引用本文:翁静艳,张建中,许根英. 便携式输注泵输注不同剂型5-氟尿嘧啶临床应用时间差异分析[J]. 中国临床医学, 2021, 28(3): 428-432
作者姓名:翁静艳  张建中  许根英
作者单位:复旦大学附属中山医院药剂科, 上海 200032
摘    要:目的:探讨便携式输注泵输注不同剂型5-氟尿嘧啶的临床应用时间差异原因,规范临床用药.方法:在实验室理想条件下,分过滤和不过滤2种情况,测定氟尿嘧啶注射液、氟尿嘧啶粉针剂在便携式输注泵中的输液时间及渗透压、pH值、澄清度、含量等可能影响流速的药学性能因素.结果:与氟尿嘧啶注射液相比,使用便携式输注泵持续输注不同氟尿嘧啶粉...

关 键 词:氟尿嘧啶粉针剂  氟尿嘧啶注射液  便携式输注泵  临床使用时间差异
收稿时间:2021-03-15
修稿时间:2021-05-08

Analysis of clinical using time difference of different dosage forms of fluorouracil injection with portable infusion pump
WENG Jing-yan,ZHANG Jian-zhong,XU Gen-ying. Analysis of clinical using time difference of different dosage forms of fluorouracil injection with portable infusion pump[J]. Chinese Journal Of Clinical Medicine, 2021, 28(3): 428-432
Authors:WENG Jing-yan  ZHANG Jian-zhong  XU Gen-ying
Affiliation:Department of Pharmacy, Zhongshan Hospital, Fudan University, Shanghai 200032, China
Abstract:Objective: To explore the difference of clinical using time of fluorouracil powder and injection in portable infusion pump, and analyze the reasons, so as to guide clinical medication. Methods: Under ideal laboratory conditions and filtering or no filtering, the infusion time, osmotic pressure, pH value, clarity and content of fluorouracil injection and fluorouracil powder in portable infusion pump were determined, which may affect the flow rate of pharmaceutical properties. Results: Compared with the continuous infusion of different fluorouracil powder injection and fluorouracil injection using portable infusion pump, fluorouracil powder injection has prolonged the infusion time. And different brand powder injection also has bigger difference, such as fluorouracil A 57 h, fluorouracil B 90 h, this is consistent with clinical use. Before the liquid was filtered, the clinical infusion speed of the two kinds of fluorouracil powder was significantly different. However, after filtration, the infusion speed of the two kinds of fluorouracil powder was basically the same as that of fluorouracil injection, and there was no significant difference in drug concentration, osmotic pressure, and pH value. Combined with the clarity test results of the drug solution, the main factor affecting the infusion time of fluorouracil powder injection in the portable infusion pump is the presence of non-drug active excipients in the preparation. Conclusions: The infusion speed of fluorouracil powder and injection in the clinical use of portable infusion pump is significantly different. The main reason for the difference in the clinical use of fluorouracil powder from different manufacturers is the difference in preparation and excipients, which suggests that attention should be paid to clinical use.
Keywords:fluorouracil powder injection  fluorouracil injection  portable infusion pump  differences in clinical using time
本文献已被 CNKI 等数据库收录!
点击此处可从《中国临床医学》浏览原始摘要信息
点击此处可从《中国临床医学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号