Contrast-enhanced MR imaging of the liver: Comparison between Gd-BOPTA and mangafodipir
Authors:Wolfgang Schima  Jan Petersein  Peter F Hahn  Mukesh Harisinghani  Elkan Halpern  Sanjay Saini
Abstract:The purpose of the study was to evaluate the MR contrast agents gadolinium benzyloxypropionictetro-acetate (Gd-BOPTA) and Mangafodipir for liver enhancement and the lesion-liver contrast on T1W spin-echo (SE) and gradient-recalled-echo (GRE) images. Fifty-one patients (three groups of 17 patients each) with known or suspected liver lesions were evaluated with T1W SE (300/12) and GRE (77-80/2.3-2.5/80°) images before and after intravenous (IV) Gd-BOPTA (0.1 or 0.05 mmol/kg) or Mangafodipir (5 μmol/kg) in phase II to III clinical trials. Quantitative analysis by calculating liver signal-to-noise ratio (SNR), lesion-liver contrast-to-noise ratio (CNR), and spleen-liver CNR was performed. Liver SNR and spleen-liver CNR were always significantly increased postcontrast. SNR was highest after application of 0.1 mmol/kg Gd-BOPTA (51.3 ± 3.6, P < .05). CNR was highest after Mangafodipir (?22.6 ± 2.7), but this was not significantly different from others (P = .07). Overall, GRE images were superior to SE images for SNR and CNR. Mangafodipir and Gd-BOPTA (0.1 mmol/kg) provide equal liver enhancement and lesion conspicuity postcontrast. By all criteria, contrast-enhanced T1-weighted GRE were comparable to SE images.
Keywords:Contrast media  effects  Liver  MR  contrast enhancement  Gadolinium  Manganese