首页 | 本学科首页   官方微博 | 高级检索  
检索        


The 40 Hz Modulation-following Response: Prediction of Low-frequency Uncomfortable Loudness Levels in Normally Hearing Adults
Abstract:Preliminary investigations have been made in normally hearing alert adults to establish whether the 40 Hz modulation-following response (MFR) can be used to predict 400 Hz uncomfortable loudness levels (ULLs). The MFR stimulus was a 400 Hz carrier, amplitude- and frequency-modulated by a 40 Hz sine function. Subjective ULLs were obtained using standard procedures. 1 Objective ULLs were obtained from MFR parameter-intensity functions using rms amplitude, phase angle and magnitude-squared coherence (40 Hz components). The best predictions of the subjective ULL were made using objective ULLs calculated from the gradients of linear best-fit lines for individual phase-intensity functions (80 per cent predicted within 10 dB of the subjective ULL; maximum deviation = 16 dB). Poorest predictions were based on inter-subject average rms amplitude-intensity functions, where as few as 14 per cent were within 10 dB of the subjective value. The best predictions were considered sufficiently accurate to warrant further investigation using a variety of modulation and carrier frequencies in different age groups and with varying degrees of hearing loss.
Keywords:Modulation-following response  Prediction  Objective  Low-frequency  Uncomfortable loudness level
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号