Dosimetry and adequacy of CT-based attenuation correction for pediatric PET: phantom study
Authors:Fahey Frederic H  Palmer Matthew R  Strauss Keith J  Zimmerman Robert E  Badawi Ramsey D  Treves S Ted
Affiliation:Division of Nuclear Medicine, Department of Radiology, Children's Hospital Boston, MA 02115, USA. frederic.fahey@childrens.harvard.edu
Abstract:PURPOSE: To evaluate the dose from the computed tomographic (CT) portion of positron emission tomography (PET)/CT to determine minimum CT acquisition parameters that provide adequate attenuation correction. MATERIALS AND METHODS: Measurements were made with a PET/CT scanner or a PET scanner, five anthropomorphic phantoms (newborn to medium adult), and an ionization chamber. The CT dose was evaluated for acquisition parameters (10, 20, 40, 80, 160 mA; 80, 100, 120, 140 kVp; 0.5 and 0.8 second per rotation; 1.5:1 pitch). Thermoluminescent dosimetry was used to evaluate the germanium 68/gallium 68 rod sources. A phantom study was performed to evaluate CT image noise and the adequacy of PET attenuation correction as a function of CT acquisition parameters and patient size. RESULTS: The volumetric anthropomorphic CT dose index varied by two orders of magnitude for each phantom over the range of acquisition parameters (0.30 and 21.0 mGy for a 10-year-old with 80 kVp, 10 mAs, and 0.8 second and with 140 kVp, 160 mAs, and 0.8 second, respectively). The volumetric anthropomorphic CT dose index for newborn phantoms was twice that for adult phantoms acquired similarly. The rod source dose was 0.03 mGy (3-minute scan). Although CT noise varied substantially among acquisition parameters, its contribution to PET noise was minimal and yielded only a 2% variation in PET noise. In a pediatric phantom, PET images generated by using CT performed with 80 kVp and 5 mAs for attenuation correction were visually indistinguishable from those generated by using CT performed with 140 kVp and 128 mAs. With very-low-dose CT (80 kVp, 5 mAs) for the adult phantom, undercorrection of the PET data resulted. CONCLUSION: For pediatric patients, adequate attenuation correction can be obtained with very-low-dose CT (80 kVp, 5 mAs, 1.5:1 pitch), and such correction leads to a 100-fold dose reduction relative to diagnostic CT. For adults undergoing CT with 5 mAs and 1.5:1 pitch, the tube voltage needs to be increased to 120 kVp to prevent undercorrection.
Keywords:
本文献已被 PubMed 等数据库收录!
点击此处可从《Radiology》浏览原始摘要信息
点击此处可从《Radiology》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号