摘    要:目的 建立并探讨一种可评价便携式血气胸引流装置引流效果的实验动物模型.方法 将18只实验犬平均分为3组:单纯血胸模型组、单纯气胸模型组和持续出血型血气胸模型组,建立动物模型后,行X线胸片或B超检查,监测建模前、建模后10、30、60 min实验犬呼吸频率、心率和末梢脉氧饱和度的变化.结果 经X线胸片或B超证实,3组实验犬建模后10 min呼吸和心率均明显升高,脉氧饱和度下降,但单纯血胸组和单纯气胸组呼吸频率、脉氧饱和度在建模后10、30、60 min 3个时间点上比较差异无统计学意义(P>0.05),心率在建模后30 min和60 min 2个时间点上比较差异无统计学意义(P>0.05),持续出血型血气胸组实验犬建模后30 min呼吸和心率开始下降,脉氧饱和度急剧下降.结论 该血气胸动物模型适用于评价便携式血气胸引流装置.

关 键 词:创伤  血气胸  动物模型

Development of an animal model used for the evaluation of the portable hematopneumothorax draining device
XUE Lei,TANG Hua,QIN Xiong,PAN Tie-wen,XU Zhi-fei,DING Xin-yu,SUN Ju-xian. Development of an animal model used for the evaluation of the portable hematopneumothorax draining device[J]. Chinese Journal of Nautical Medicine and Hyperbaric Medicine, 2009, 16(3). DOI: 10.3760/cma.j.issn.1009-6906.2009.03.017
Authors:XUE Lei  TANG Hua  QIN Xiong  PAN Tie-wen  XU Zhi-fei  DING Xin-yu  SUN Ju-xian
Abstract:Objective To investigate an animal model used for the evaluation of the efficiency of the portable hematopneumothorax draining device.Methods Eighteen dogs were equally divided into three groups,i.e.the pure hemathorax group,the pure pneumothorax group,and the prolonged hematopneumothorax group.Following development of the animal model,Chest X-ray film and uhrasonography were implemented to measure the respiratory frequency,heart rate and change pattern of oxygen saturation in peripheries of the experimental animals,pre-experiment,10 min,30 min and 60 min after the development of the model.Results Chest X-ray and ultrasonography revealed that respiratory frequency,heart rate of the three animal groups elevated significantly,while oxygen saturation dropped markedly 10 minutes after the development of the model.However,for the pure hemathorax and pneumothorax groups,no significant differences were noted in the respiratory frequency and oxygen saturation at 10 min,30 min and 60 min after the development of the model.And there were no differences in heart rate,which increased again 30 min after the development of the model,when comparisons were made between the two time points of 30 min and 60 min.Respiratory frequency and heart rate for the prolonged hematopneumothorax group began to decrease and oxygen saturation dropped sharply,30 min after the development of the model.Conclusions This animal model is suitable for the evaluation of the efficiency of the portable hematopneumothorax draining device used in the animal experiments.
Keywords:Trauma  Hematopneumothorax  Animal model
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号