首页 | 本学科首页   官方微博 | 高级检索  
检索        


Intravascular Ultrasound-Derived Minimal Lumen Area Criteria for Functionally Significant Left Main Coronary Artery Stenosis
Institution:1. Department of Cardiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea;2. Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, South Korea
Abstract:ObjectivesThis study sought to evaluate the intravascular ultrasound (IVUS) minimal lumen area (MLA) for functionally significant left main coronary artery (LMCA) stenosis using fractional flow reserve (FFR) as the standard.BackgroundThe evaluation of significant LMCA stenosis remains challenging.MethodsWe identified 112 patients with isolated ostial and shaft intermediate LMCA stenosis (angiographic diameter stenosis of 30% to 80%) who underwent IVUS and FFR measurement.ResultsThe FFR was ≤0.80 in 66 LMCA lesions (59%); these exhibited smaller reference vessels, smaller minimal lumen diameter, greater diameter of stenosis, longer lesion length, smaller MLA, larger plaque burden, and more frequent plaque rupture. The independent factors of an FFR of ≤0.80 were plaque rupture (odds ratio OR]: 4.47; 95% Confidence Interval (CI): 1.35 to 14.8; p = 0.014); body mass index (OR: 1.19; 95% CI: 1.00 to 1.41; p = 0.05), age (OR: 0.95; 95% CI: 0.90 to 1.00; p = 0.031), and IVUS MLA (OR: 0.37; 95% CI: 0.25 to 0.56; p < 0.001). The optimal IVUS MLA cutoff value for an FFR of ≤0.80 was 4.5 mm2 (77% sensitivity, 82% specificity, 84% positive predictive value, 75% negative predictive value, area under the curve: 0.83, 95% CI: 0.76 to 0.96; p < 0.001) overall and 4.1 to 4.5 mm2 in various subgroups. Adjustment for the body surface area, body mass index, and left ventricular mass did not improve the diagnostic accuracy of the IVUS MLA.ConclusionsIn patients with isolated ostial and shaft intermediate LMCA stenosis, an IVUS-derived MLA of ≤4.5 mm2 is a useful index of an FFR of ≤0.80.
Keywords:coronary disease  fractional flow reserve  intravascular ultrasound  left main coronary artery  CI"}  {"#name":"keyword"  "$":{"id":"kwrd0030"}  "$$":[{"#name":"text"  "_":"confidence interval  FFR"}  {"#name":"keyword"  "$":{"id":"kwrd0040"}  "$$":[{"#name":"text"  "_":"fractional flow reserve  IVUS"}  {"#name":"keyword"  "$":{"id":"kwrd0050"}  "$$":[{"#name":"text"  "_":"intravascular ultrasound  LMCA"}  {"#name":"keyword"  "$":{"id":"kwrd0060"}  "$$":[{"#name":"text"  "_":"left main coronary artery  LV"}  {"#name":"keyword"  "$":{"id":"kwrd0070"}  "$$":[{"#name":"text"  "_":"left ventricular  MLA"}  {"#name":"keyword"  "$":{"id":"kwrd0080"}  "$$":[{"#name":"text"  "_":"minimal lumen area  OR"}  {"#name":"keyword"  "$":{"id":"kwrd0090"}  "$$":[{"#name":"text"  "_":"odds ratio  QCA"}  {"#name":"keyword"  "$":{"id":"kwrd0100"}  "$$":[{"#name":"text"  "_":"quantitative coronary angiogram
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号