首页 | 本学科首页   官方微博 | 高级检索  
     

杭州市部分非医疗机构辐射水平分析
引用本文:赵徵鑫,王强,曹承建,杨勇,王海华,翟贺争. 杭州市部分非医疗机构辐射水平分析[J]. 中国辐射卫生, 2021, 30(1): 59-62. DOI: 10.13491/j.issn.1004-714X.2021.01.013
作者姓名:赵徵鑫  王强  曹承建  杨勇  王海华  翟贺争
作者单位:1. 杭州市职业病防治院,浙江 杭州 310014;2. 中国医学科学院放射医学研究所;3. 天津大学
基金项目:浙江省医药卫生科技计划(2121KY956);协和青年科研基金(33320195101);中国医学科学院放射医学研究所产业化培育孵化项目(202005);杭州市科技发展计划(20201203B220)
摘    要:目的 了解杭州市部分非医疗机构辐射防护现状,为相关主管部门制定非医疗机构放射性危害因素监测规划提供依据和参考。方法 采用问卷调查和现场检测相结合的方式对杭州市5家非医疗监测机构的人员防护用品配置及放射源和射线装置的辐射水平进行调查与分析。结果 5家监测机构均已开展个人剂量监测,且个人年剂量当量满足国家相关标准的要求;放射源和射线装置机房周围剂量当量率检测结果均低于检测仪器的最低探测下限;储源状态时,距源容器外表面5 cm 和100 cm处的最大周围剂量当量率值分别为22.2 μSv/h和2.0 μSv/h;源使用状态时,距源容器外表面5 cm 和100 cm处的最大周围剂量当量率值分别为44.3 μSv/h和5.0 μSv/h。结论 正常运行状态下,杭州市部分非医疗监测机构的放射源和射线装置所产生的辐射剂量水平处于低水平状态,但部分距源容器外表面周围剂量当量率值处于较高水平,非医疗机构需提高辐射防护意识,加强辐射管理工作。

关 键 词:非医疗机构  辐射水平  辐射防护  
收稿时间:2020-07-09

Radiation level analysis of some non-medical institutions in Hangzhou
ZHAO Zhixin,WANG Qiang,CAO Chengjian,YANG Yong,WANG Haihua,ZHAI Hezheng. Radiation level analysis of some non-medical institutions in Hangzhou[J]. Chinese Journal of Radiological Health, 2021, 30(1): 59-62. DOI: 10.13491/j.issn.1004-714X.2021.01.013
Authors:ZHAO Zhixin  WANG Qiang  CAO Chengjian  YANG Yong  WANG Haihua  ZHAI Hezheng
Affiliation:1. Hangzhou Hospital for the Prevention and Treatment of Occupational Disease, Hanghzou 310014 China;2. Institute of Radiation Medicine, Chinese Academy of Medical Sciences;3. Tianjin University
Abstract:Objective The purpose of this study is to grasp the current situation of radiation protection in some non-medical institutions in Hangzhou, and to provide basis and reference for the relevant authorities departments to make the radioactive hazard factors monitoring plan for non-medical institutions.Methods The configuration of the personnel protective equipment and radiation level of radiation sources and radiation devices in 5 non-medical monitoring institutions in Hangzhou were investigated and analyzed by means of questionnaire survey and on-site detection.Results The radiation workers of 5 monitoring institutions have carried out personal dose monitoring, and their annual individual dose equivalent meets the requirements of relevant national standards. The ambient dose equivalent rates around the radiation source and radiation device room are lower than the minimum detection limit of the instrument. When the source is stored, the maximum ambient dose equivalent rates at 5 cm and 100 cm away from the external surface of the source container were 22.2 μSv/h and 2.0 μSv/h, respectively. When the source is in use, the maximum ambient dose equivalent rates at 5 cm and 100 cm away from the external surface of the source container were 44.3 μSv/h and 5.0 μSv/h, respectively.Conclusion Under normal operation, the radiation dose level of some non-medical monitoring institutions in Hangzhou is at a low level, while the ambient dose equivalent rates around the external surface of the source container is at a high level. Therefore, non-medical institutions should improve their awareness of radiation protection and strengthen radiation management.
Keywords:Non-medical Institutions  Radiation Level  Radiation Protection  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国辐射卫生》浏览原始摘要信息
点击此处可从《中国辐射卫生》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏