AccuContour软件自动勾画胸腹部肿瘤患者两种胃结构比较
引用本文:秦伟,庄洁颖,时飞跃,赵紫婷,王敏,赵环宇,魏晓为. AccuContour软件自动勾画胸腹部肿瘤患者两种胃结构比较[J]. 中国辐射卫生, 2021, 30(3): 264-268. DOI: 10.13491/j.issn.1004-714X.2021.03.004
作者姓名:秦伟  庄洁颖  时飞跃  赵紫婷  王敏  赵环宇  魏晓为
作者单位:1. 南京医科大学附属南京医院(南京市第一医院)肿瘤放疗中心,江苏 南京 210006;2. 南京医科大学医学物理研究中心,江苏 南京 210029;3. 南京医科大学附属南京医院(南京市第一医院)医疗设备处,江苏 南京 210006
基金项目:国家自然科学基金面上项目(81773240);江苏省自然科学基金面上项目(BK20181118)
摘    要:目的 使用基于深度学习的AccuContour软件自动勾画胸腹部肿瘤患者正常胃和胸腔胃结构,对勾画效果进行评估和比较.方法 选取36例胸腹部肿瘤患者,分为2组,其中18例正常胃患者为A组,其余18例食管癌术后胸腔胃患者为B组.使用AccuContour软件在患者的定位CT图像上自动勾画胃结构,对自动勾画和手工勾画的体积...

关 键 词:自动勾画    胸腔胃  放射治疗
收稿时间:2021-01-22

Comparison of the automatic delineation of two kinds of stomach by the AccuContour software for patients with thoracic and abdominal tumors
QIN Wei,ZHUANG Jieying,SHI Feiyue,ZHAO Ziting,WANG Min,ZHAO Huanyu,WEI Xiaowei. Comparison of the automatic delineation of two kinds of stomach by the AccuContour software for patients with thoracic and abdominal tumors[J]. Chinese Journal of Radiological Health, 2021, 30(3): 264-268. DOI: 10.13491/j.issn.1004-714X.2021.03.004
Authors:QIN Wei  ZHUANG Jieying  SHI Feiyue  ZHAO Ziting  WANG Min  ZHAO Huanyu  WEI Xiaowei
Affiliation:1. Radiation Therapy Center, Nanjing First Hospital, Nanjing Medical University, Nanjing 210006 China;2. Center of Medical Physics with Nanjing Medical University, Nanjing 210029 China;3. Department of Medical Equipment, Nanjing First Hospital, Nanjing Medical University, Nanjing 210006 China
Abstract:Objective To delineate the normal stomach and thoracic stomach structure of patients with thoracic and abdominal tumor automatically using the AccuContour software based on deep learning in order to evaluate and compare the results.Methods Thirty-six patients with choracic and abdominal tumors were chosen for this study, and were divided into two groups. Group A included 18 patients with normal stomach, and group B included the other 18 patients undergoing esophageal carcinoma operation with thoracic stomach. The stomach structures were automatically delineated by the AccuContour software in the simulation CT series. Statistical analysis was carried out to data of the differences in volume, position and shape between the automatic and manual delineations, and data of the two kinds of stomach were compared.Results For group A, the differences in volume (ΔV%) between the automatic and manual delineations was (-1.82 ±9.65)%, the total position difference (ΔL) was (0.51 ±0.37) cm, the values of dice similarity coefficient (DSC) was 0.89 ±0.04. There were significant differences in values of ΔV%ΔL and DSC (P < 0.05).Conclusion The used version of AccuContour software in this study had a satisfactory result of automatic delineation of the normal stomach structure larger than certain volume, but could not delineate the thoracic stomach structures effectively for patients undergoing esophageal carcinoma operation.
Keywords:Automatic Delineation  Stomach  Thoracic Stomach  Radiotherapy  