Complications associated with central venous catheters used for the collection of peripheral blood progenitor cells to support high-dose chemotherapy and autologous stem cell rescue
Authors:B. R. Meisenberg  Mary Callaghan  Christine Sloan  Laurie Sampson  William E. Miller  Robert McMillan
Affiliation:(1) Bone Marrow Transplant Program, MS312, Scripps Clinic and Research Foundation, 10666 North Torrey Pines Road, La Jolla, CA 92037, USA, US
Abstract: The purpose of this study was to review the incidence and type of complications associated with the insertion and use of central venous catheters for leukapheresis and high-dose chemotherapy with stem cell rescue. One hundred sixty-seven central venous catheters placed either at the transplant center or by various community surgeons were studied for insertion complications, inability to perform leukapheresis and incidence of infection. The overall incidence of hemo- or pneumothorax was 3.6%. Inability to pherese occurred in 13% of catheters placed by outside surgeons and 6.5% of catheters inserted at the transplant institution. Most often, these were due to malposition of the catheter too high in the superior vena cava or in other veins. Deep venous thrombosis was often related to this malposition and occurred in 4.8% of all patients. Pulmonary embolism was not seen in these patients despite the fact the catheters were often left in place during the thrombotic episode. Early or late-onset infections occurred in 6.5% of patients and were most often exit site infections. The incidence of complications of pheresis catheters is high but might be reduced by more attention to proper placement of the catheter closer to the right atrial/superior vena cava junction, and limiting insertion to a cadre of surgeons familiar with leukapheresis requirements.
Keywords:  Central venous catheters  High-dose chemotherapy  Stem cell transplant
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号