首页 | 本学科首页   官方微博 | 高级检索  
检索        

气道支架置入术治疗恶性气道狭窄伴一侧肺通气的临床研究
引用本文:文芳静,史小武.气道支架置入术治疗恶性气道狭窄伴一侧肺通气的临床研究[J].山东大学学报(医学版),2016,54(12):62-66.
作者姓名:文芳静  史小武
作者单位:武汉市中心医院呼吸内科, 湖北 武汉 430014
摘    要:目的 评价气道支架置入术在恶性气道狭窄伴一侧肺通气治疗中的价值。 方法 选择2011年1月至2015年2月武汉市中心医院呼吸内科收住的34例恶性气道狭窄伴一侧肺通气的患者,根据狭窄的病因、部位行支架置入术,评价近期疗效、气道开放程度和肺功能及并发症情况。 结果 支架置入术后34例患者呼吸困难症状明显缓解,狭窄段直径增大,气促评级改善,1秒用力呼气容积(FEV1)及动脉血氧分压(PaO2)上升,二氧化碳分压(PaCO2)改善,差异有统计学意义(P<0.05)。2周内不良反应:刺激性咳嗽7例(20.59%),咽痛9例(26.47%),咯血10例(29.41%);随访1个月并发症:肉芽组织增生3例(8.82%),排痰困难5例(14.71%),均给予对症处理后改善,1例(2.94%)27 d后大咯血死亡。 结论 电子支气管镜下气道支架置入术治疗恶性气道狭窄伴一侧肺通气的可靠性和安全性较高,值得临床推广。

关 键 词:气道支架  恶性气道狭窄  一侧肺通气  
收稿时间:2015-12-31

Clinical research of stent placement by electronic bronchoscopy on malignant airway stenosis with one side lung ventilation
WEN Fangjing,SHI Xiaowu.Clinical research of stent placement by electronic bronchoscopy on malignant airway stenosis with one side lung ventilation[J].Journal of Shandong University:Health Sciences,2016,54(12):62-66.
Authors:WEN Fangjing  SHI Xiaowu
Institution:Department of Respiratory Disease, Central Hospital of Wuhan, Wuhan 430014, Hubei, China
Abstract:Objective To evaluate the value of airway stent placement by electronic bronchoscopy on malignant airway stenosis with one side lung ventilation. Methods Thirty-four patients in the Department of Respiratory Disease of Central Hospital of Wuhan from January 2011 to February 2015 were included. Airway stent was used to evaluate the short-term therapeutic effects, airways opening degree, pulmonary functions and complications. Results Follow up for one month, the symptoms of dyspnea were relieved. Airway diameter, dyspnea score, forced expiratory volume in one second(FEV1), partial pressure of oxygen(PaO2), partial pressure of carbon dioxide(PaCO2)were improved significantly(P<0.05). Adverse reactions in 2 weeks were cough(7 cases, 20.59%), sore throat(9 cases, 26.47%), and hemoptysis(10 cases, 29.41%). With the follow-up for one month,airway granulation proliferation occurred in 3 patients(8.82%), sputum drainage difficulty in 5 patients(14.71%), and 1 patient(2.94%)died because of massive hemoptysis after 27 days. Conclusion Stent placement by electronic bronchoscopy for malignant airway stenosis with one side lung ventilation is effect and safe, worthy to be promoted clinically.
Keywords:Airway stent  Malignant airway stenosis  One side lung ventilation  
点击此处可从《山东大学学报(医学版)》浏览原始摘要信息
点击此处可从《山东大学学报(医学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号