首页 | 本学科首页   官方微博 | 高级检索  
     

可吸收内固定材料修复髌骨横断性骨折
引用本文:王 峰,贾金领. 可吸收内固定材料修复髌骨横断性骨折[J]. 中国组织工程研究, 2016, 20(8): 1126-1132. DOI: 10.3969/j.issn.2095-4344.2016.08.009
作者姓名:王 峰  贾金领
作者单位:南阳市中心医院骨二科,河南省南阳市 473000;新乡医学院第一附属医院,河南省新乡市 453100
摘    要:

关 键 词:生物材料  骨生物材料  可吸收材料  髌骨骨折  横断性骨折  内固定  生物相容性  
收稿时间:2016-01-07

Absorbable internal fixation materials in the repair of patellar transverse fractures
Wang Feng,Jia Jin-ling. Absorbable internal fixation materials in the repair of patellar transverse fractures[J]. Chinese Journal of Tissue Engineering Research, 2016, 20(8): 1126-1132. DOI: 10.3969/j.issn.2095-4344.2016.08.009
Authors:Wang Feng  Jia Jin-ling
Affiliation:Second Department of Orthopedics, Nanyang City Central Hospital, Nanyang 473000, Henan Province, China; First Affiliated Hospital of Xinxiang Medical University, Xinxiang  453100, Henan Province, China
Abstract:BACKGROUND: In recent years, all kinds of absorbable internal fixation materials have been used in the clinical treatment of patellar transverse fractures.OBJECTIVE: To investigate the repairing effect of absorbable internal fixation materials on patellar transverse fractures.METHODS: Totally 102 cases of fresh patellar transverse fractures were included 62 males and 40 females cases, with a mean age of (41.85±11.15) years, and according to treatment methods, they were divided into two groups: observation group (n=52) using absorbable screws for reconstruction and control group (n=50) using Kirschner wire repair. At 12 months after repair, Lysholm knee function score were measured and evaluated, and the occurrence of adverse events was recorded.RESULTS AND CONCLUSION: The knee function score and excellent rate of the observation group were significantly higher than those of the control group (both P < 0.05). In the observation group, there were four cases of fracture displacement, but no skin irritation and other adverse events occurred; in the control group, there were two cases of nonunion and five cases of skin irritation or internal fixation loosening and slippage. Therefore, there was a higher incidence of adverse events in the control group compared with the observation group (P < 0.05). These experimental results show that the use of absorbable screws in the repair of patellar transverse fracture can promote the functional recovery of the knee joint, with good biocompatibility. 
Keywords:
点击此处可从《中国组织工程研究》浏览原始摘要信息
点击此处可从《中国组织工程研究》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号