首页 | 本学科首页   官方微博 | 高级检索  
检索        

三维超声心动图评估发育不良型三尖辦结构的价值
引用本文:陈笋,孙锟,陈树宝,张玉奇,张志芳,吴兰萍.三维超声心动图评估发育不良型三尖辦结构的价值[J].中华超声影像学杂志,2009,18(7).
作者姓名:陈笋  孙锟  陈树宝  张玉奇  张志芳  吴兰萍
作者单位:上海交通大学医学院附属上海儿童医学中心心内科,200127
基金项目:上海市教育委员会资助课题 
摘    要:目的 应用三维超声心动图探讨右心室发育不良时三尖辦装置的结构特点.方法 28例诊断为右心室发育不良的患儿,按照三尖辦反流程度分为反流组(三尖辦反流中度及以上)与非反流组(三尖辦反流轻度及以下).18例年龄匹配的正常儿童作为对照组.应用实时三维超声心动图测定右心室容积、三尖辦辦环面积、三尖辦各辦叶的面积以及辦尖至最近乳头肌顶点的距离.测值应用体表面积(USA)进行标化.结果 右心室发育不良患儿组的右心室容积显著低于正常组,三尖辦辦环面积与右心室容积显著相关(r=0.90,P<0.0001).在三尖辦反流组,三尖辦前辦面积与辦环面积的比值较非反流组以及正常组显著增加,而后辦所占比值显著缩小.右心发育不良组各辦尖至相邻乳头肌顶点的距离显著小于正常组.反流组隔辦辦尖至相邻乳头肌距离显著小于非反流组(P=0.0023).结论 三维超声心动图可以用来评估先天性心脏病三尖辦病变.右心室发育不良患儿后辦发育不良以及隔辦腱索偏短可能是三尖辦反流的原因.

关 键 词:超声心动描记术  三维  心脏缺损  先天性  三尖辦发育不良

Evaluation of the structure of tricuspid valve with three dimensional echocardiography in hypoplastic right ventricle
CHEN Sun,SUN Kun,CHEN Shu-bao,ZHANG Yu-qi,ZHANG Zhi-fang,WU Lan-ping.Evaluation of the structure of tricuspid valve with three dimensional echocardiography in hypoplastic right ventricle[J].Chinese Journal of Ultrasonography,2009,18(7).
Authors:CHEN Sun  SUN Kun  CHEN Shu-bao  ZHANG Yu-qi  ZHANG Zhi-fang  WU Lan-ping
Abstract:Objective To reveal the character of tricuspid valve in hypoplastic right ventricular heart syndrome (HPRVHS) using 3-dimensional echocardiography(3DE). Methods Twenty eight patients with HPRVHS were included in the study, and they were divided into two groups according the degree of tricuspid regurgitation. Eighteen normal children were included as the control. Volume of right ventricle(VRV), area of tricuspid annulus(TVA),proportion of the leaflets and the distance from tips of leaflets to the nearest papillary muscle were measured with 3DE. These data was standardized by body surface area. Results The volume of right ventricle in HPRVHS was significantly less than that in normal group. The area of tricuspid annulus was significantly correlated with volume of right ventricle(r = 0. 90, P < 0. 0001). In the tricuspid regurgitation group, the proportion of area of anterior leaflet to area of tricuspid annulus was significantly higher than non-regurgitation group and normal group(P <0. 0001). Respectively,the proportion of the area of posterior leaflet to the area of tricuspid annulus in regurgitation group was significantly less than normal and non-regurgitation group. The distance from tips of leaflets was significantly shorter in HPRVHS than in normal group. Furthermore, the distance from the tip of septal leaflet to the nearest papillary muscle was shorter in regurgitation group than non-regurgitation group ( P = 0. 0023). Conclusions 3DE could be applied for evaluating the pathologic change of tricuspid valve in congenital heart disease. In HPRVHS, hypoplastic of posterior leaflet and shortness of the cords of septal leaflet could be the cause of tricuspid regurgitation.
Keywords:Echocardiography  three-dimensional (Heart defects  congenital  Hypoplastic tricuspid valve
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号