首页 | 本学科首页   官方微博 | 高级检索  
检索        


Effect of transcatheter aortic valve implantation on QT dispersion in patients with aortic stenosis
Authors:Hakan Erkan  Engin Hatem  Mustafa Tarik Aga  Levent Korkmaz  Teyyar Gokdeniz  Ahmet Cagri Aykan  Ezgi Kalaycioglu  Faruk Boyaci  Omer Faruk Cirakoglu and Sukru Celik
Institution:Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Kafkas University Hospital, Kars, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey;Department of Cardiology, Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Camlik Street, Trabzon 61040, Turkey
Abstract:Background QT dispersion (QTd) is a predictor of ventricular arrhythmia. Ventricular arrhythmia is an important factor influencing morbidity and mortality in patients with aortic stenosis. Surgical aortic valve replacement reduced the QTd in this patients group. However, the effect of transcatheter aortic valve implantation (TAVI) on QTd in patients with aortic stenosis is unknown. The aim of this study was to investigate the effect of TAVI on QTd in patients with aortic stenosis. Methods Patients with severe aortic stenosis, who were not candidates for surgical aortic valve replacement due to contraindications or high surgical risk, were included in the study. All patients underwent electrocardiographic and echocardiographic evaluation before, and at the 6th month after TAVI, computed QTd and left ventricular mass index (LVMI). Results A total 30 patients were admitted to the study (mean age 83.2 ± 1.0 years, female 21 and male 9, mean valve area 0.7 ± 3 mm2). Edwards SAPIEN heart valves, 23 mm (21 patients) and 26 mm (9 patients), by the transfemoral approach were used in the TAVI procedures. All TAVI procedures were successful. Both QTd and LVMI at the 6th month after TAVI were significantly reduced compared with baseline values of QTd and LVMI before TAVI (73.8 ± 4 ms vs. 68 ± 2 ms, P = 0.001 and 198 ± 51 g/m2 vs.. 184 ± 40 g/m2, P = 0.04, respectively). There was a significant correlation between QTd and LVMI (r = 0.646, P < 0.001). Conclusion QTd, which malign ventricular arrhythmia marker, and LVMI were significantly reduced after TAVI procedure. TAVI may decrease the possibility of ventricular arrhythmia in patients with aortic stenosis.
Keywords:Aortic stenosis  QT dispersion  Transcatheter aortic valve implantation
本文献已被 维普 等数据库收录!
点击此处可从《老年心脏病学杂志(英文版)》浏览原始摘要信息
点击此处可从《老年心脏病学杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号