Reliability of the rabbit postero‐lateral spinal fusion model: A meta‐analysis |
| |
Authors: | Alexander M. Riordan Rajesh Rangarajan Joshua W. Balts Wellington K. Hsu Paul A. Anderson |
| |
Affiliation: | 1. Department of Orthopedic Surgery, University of Wisconsin School of Medicine and Public Health, UWMFCB 6215, , Madison, Wisconsin, 53705;2. Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, , Chicago, Illinois |
| |
Abstract: | The rabbit model of spinal fusion with the autogenous iliac crest bone graft (ICBG) control is widely used to evaluate bone graft substitutes and enhancers. This study examined the reliability of this model using meta‐analysis. A systematic literature search from January 1995 to May 2011 identified 56 studies, involving 733 animals. The primary outcome was fusion success calculated as logit event rate. Study design, surgical technique, rabbit characteristics (gender, species, age, weight), and institution were analyzed. Overall fusion success was 52.4%. Important positive variables were time‐point >4 weeks, ICBG dose >1 cm3, initial weight of animals ≥3 kg, level at L4‐5 or L5‐6, and age ≥6 months. Inter‐ and intra‐institutional reliability was excellent. The rabbit model ICBG control group is reliable, although several factors can affect results. Fusion under normal handling occurs reliably in 5 weeks. The volume of bone graft should be >1 cm3 but no benefits are present with >2 cm3. The animals should weigh a minimum of 3 kg and be at least 6 months old. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1261–1269, 2013 |
| |
Keywords: | meta‐analysis spinal lumbar fusion rabbits autograft |
|
|