Biomechanical and rheological characterization of mild intervertebral disc degeneration in a large animal model
Authors:Suzanne EL Detiger  Roel JW Hoogendoorn  Albert J van der Veen  Barend J van Royen  Marco N Helder  Gijsje H Koenderink  Theo H Smit
Institution:1. Department of Orthopaedic Surgery, VU University Medical Center, Amsterdam, The Netherlands;2. Skeletal Tissue Engineering Group Amsterdam (STEGA) and Research Institute MOVE, Amsterdam, The Netherlands;3. Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands;4. FOM Institute AMOLF, Amsterdam, The Netherlands
Abstract:Biomechanical properties of healthy and degenerated nucleus pulposus (NP) are thought to be important for future regenerative strategies for intervertebral disc (IVD) repair. However, which properties are pivotal as design criteria when developing NP replacement materials is ill understood. Therefore, we determined and compared segmental biomechanics and NP viscoelastic properties in normal and mildly degenerated discs. In eight goats, three lumbar IVDs were chemically degenerated using chondroitinase ABC (CABC), confirmed with radiography and MRI after euthanasia 12 weeks post‐operative. Neutral zone (NZ) stiffness and range of motion (ROM) were determined sagitally, laterally, and rotationally for each spinal motion segment (SMS) using a mechanical testing device. NPs were isolated for oscillatory shear experiments; elastic and viscous shear moduli followed from the ratio between shear stress and strain. Water content was quantified by weighing before and after freeze‐drying. Disc height on radiographs and signal intensity on MRI decreased (6% and 22%, respectively, p < 0.01) after CABC treatment, confirming that chemical degeneration provides a good model of disc degeneration. Furthermore, CABC‐injected IVDs had significantly lower NZ stiffness and larger ROM in lateral bending (LB) and axial rotation (AR) than controls. Rheometry consistently revealed significantly lower (10–12%) viscoelastic moduli after mild degeneration within goats, though the inter‐animal differences were relatively large (complex modulus ~12 to 41 kPa). Relative water content in the NP was unaffected by CABC, remaining at ~75%. These observations suggest that viscoelastic properties have a marginal influence on mechanical behavior of the whole SMS. Therefore, when developing replacement materials the focus should be on other design criteria, such as biochemical cues and swelling pressure. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 703–709, 2013
Keywords:nucleus pulposus  biomechanics  viscoelasticity  animal model  disc degeneration
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号