首页 | 本学科首页   官方微博 | 高级检索  
检索        


Saturation‐recovery metabolic‐exchange rate imaging with hyperpolarized [1‐13C] pyruvate using spectral‐spatial excitation
Authors:Rolf F Schulte  Jonathan I Sperl  Eliane Weidl  Marion I Menzel  Martin A Janich  Oleksandr Khegai  Markus Durst  Jan Henrik Ardenkjaer‐Larsen  Steffen J Glaser  Axel Haase  Markus Schwaiger  Florian Wiesinger
Institution:1. GE Global Research, Munich, Germany;2. Department for Nuclear Medicine, Technische Universit?t München, Munich, Germany;3. Department of Chemistry, Technische Universit?t München, Munich, Germany;4. IMETUM, Technische Universit?t München, Munich, Germany;5. GE Healthcare, Copenhagen, Denmark;6. Department of Electrical Engineering, Technical University of Denmark, Copenhagen, Denmark
Abstract:Within the last decade hyperpolarized 1‐13C] pyruvate chemical‐shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time‐resolved, multislice chemical shift imaging of the injected substrate and obtained downstream metabolites. Using spectral‐spatial excitation in combination with single‐shot spiral data acquisition, the overall encoding is evenly distributed between excitation and signal reception, allowing the encoding of one full two‐dimensional metabolite image per excitation. The signal‐to‐noise ratio can be flexibly adjusted and optimized using lower flip angles for the pyruvate substrate and larger ones for the downstream metabolites. Selectively adjusting the excitation of the down‐stream metabolites to 90° leads to a so‐called “saturation‐recovery” scheme with the detected signal content being determined by forward conversion of the available pyruvate. In case of repetitive excitations, the polarization is preserved using smaller flip angles for pyruvate. Metabolic exchange rates are determined spatially resolved from the metabolite images using a simplified two‐site exchange model. This novel contrast is an important step toward more quantitative metabolic imaging. Goal of this work was to derive, analyze, and implement this “saturation‐recovery metabolic exchange rate imaging” and demonstrate its capabilities in four rats bearing subcutaneous tumors. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Keywords:metabolic imaging  hyperpolarization  [1‐13C]  pyruvate  saturation‐recovery  metabolic exchange rate  magnetic resonance spectroscopy  spectral‐spatial excitation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号