首页 | 本学科首页   官方微博 | 高级检索  
     

吡喹酮水凝胶栓剂的含量测定
引用本文:刘祖梅. 吡喹酮水凝胶栓剂的含量测定[J]. 现代医药卫生, 2005, 21(21): 2893-2893
作者姓名:刘祖梅
作者单位:荆门职业技术学院医学分院,湖北,荆门,448000
摘    要:目的:制备吡喹酮水凝胶栓剂,并建立其含量测定方法。方法:用紫外分光光度法测定凝胶栓剂中吡喹酮的含量。结果:吡喹酮在0.2 ̄1.0mg/ml(r=0.9999)浓度范围内呈良好线性关系。平均加样回收率和相对标准偏差(RSD)为(102.44±0.69)%。结论:该处方设计合理,制备工艺可靠,质量稳定。

关 键 词:吡喹酮  水凝胶栓剂  泊洛沙姆
文章编号:1009-5519(2005)21-2893-01
收稿时间:2005-08-01
修稿时间:2005-08-01

Preparation and determination of the content of thermo-reversible praziquantel liquid suppository
LIU Zu-mei. Preparation and determination of the content of thermo-reversible praziquantel liquid suppository[J]. JOURNAL OF MODERN MEDICINE & HEALTH, 2005, 21(21): 2893-2893
Authors:LIU Zu-mei
Abstract:Objective:To prepare the thermo-reversible praziquantel liquid suppository and establish the determination method of its content.Methods:The content of praziquantel in the thermo-reversible liquid suppository was measured by ultraviolet spectrophotometry.Results:The linear response range was 0.2~10 mg.ml-1(r=0.9999).The mean recovery was 102.44% with RSD=0.69%.Conclusion:The formulation is reasonable and the preparation is stable.
Keywords:Praziquantel  Thermo-reversible liquid suppository  Poloxamer
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏