Fixation of displaced femoral neck fractures: A comparison between sliding screw plate and four cancellous bone screws |
| |
Authors: | Frank Madsen Frank Linde Erik Andersen Hanne Birke Inge Hvass Torben D. Poulsen |
| |
Affiliation: | a Department of Orthopedics, Esbjerg Central Hospital, Denmark |
| |
Abstract: | In a prospective, randomized trial, 104 consecutive patients with displaced femoral neck fractures were allocated either to fixation with a sliding screw plate or 4 ASIF cancellous bone screws. The patients were reexamined at fixed intervals to determine the time of union. The 2-year-cumulated rate of union was 64 per cent in the plate group and 84 per cent in the screw group. |
| |
Keywords: | |