首页 | 本学科首页   官方微博 | 高级检索  
检索        

椎弓根内固定技术的并发症分析
作者姓名:Weng XS  Qiu GX  Zhang J  Li SG  Yang XY  Wang YP  Zhang JG  Ye QB  Lin J  Tian Y
作者单位:中国医学科学院中国协和医科大学协和医院骨科,北京,100730
摘    要:目的 分析治疗脊柱疾病的椎弓根内固定手术在术中、术后发生并发症的原因,以便提出防治措施。方法 对本科1988-1999年采用椎弓根内固定技术治疗脊柱疾病的475例患者的资料进行回顾性总结并结合随访结果进行统计、分析。结果 428例获随访(占90.1%)。术中并发症26例,发生率5.5%;术后并发症64例,发生率15%。并发症主要发生在采用CD、DRFS、Dick、RF及Steffee等5种椎弓根内固定技术时,共72例,占总并发症例数的80%,上述5种椎弓根内固定技术的术中/术后并发症发生率依次为:CD技术0-12.9%、DRFS技术6.8%-11.9%,Dick技术7.3-12.7%,RF技术2.4%-19.5%,Steffee技术10.1%-21.5%。主要并发症包括假关节、椎弓根螺钉断裂、椎弓根螺钉位置不正确等。引起并发症的主要原因包括对椎弓根内固定技术掌握不熟练、内植物设计本身存在的缺陷等。结论 椎弓根内固定技术的并发症不容忽视,引起并发症主要原因是椎弓根内固定技术熟练程度不够及内植物本身设计上的缺陷。

关 键 词:并发症  椎弓根螺钉  内固定术  脊柱疾病  疾病预防
修稿时间:2001年9月6日

Complications associated with the technique of pedicle screw fixation
Weng XS,Qiu GX,Zhang J,Li SG,Yang XY,Wang YP,Zhang JG,Ye QB,Lin J,Tian Y.Complications associated with the technique of pedicle screw fixation[J].Acta Academiae Medicinae Sinicae,2002,24(3):294-297.
Authors:Weng Xi-sheng  Qiu Gui-xing  Zhang Jia  Li Shu-gang  Yang Xin-yu  Wang Yi-peng  Zhang Jian-guo  Ye Qi-bin  Lin Jin  Tian Ye
Institution:Department of Orthopaedics, PUMC Hospital, CAMS and PUMC, Beijing 100730, China. xshweng@yahoo.com
Abstract:OBJECTIVE: To analyze the causes of the complications associated with the pedicle screw fixation during and after operation, as well as the methods for prevention and treatment. METHODS: From January 1988 to December 1999, 475 patients who underwent pedicle screw fixation for various spinal disorders were reviewed retrospectively with statistical analysis. RESULTS: Four hundred and twenty-eight patients (90.1% of all) were followed up for (6.0 +/- 3.7) years. Complications of CD, DRFS, Dick, RF and steffee among 72 cases (80% of all) occurred during the operation of pedical screw fixation in 26 cases with the incidence of 5.5% and after the operation in 64 cases with the incidence of 15%. The incidence of operative/postoperative complications were 0-12.9% in CD, 6.8%-11.9% in DRFS, 7.3%-12.7% in Dick, 2.4%-19.5% in RF, and 10.1%-21.5% in Steffee respectively. The main complications included pseudoarthrosis, pedicle screw broken, pedicle screw malposition and so on. The complications were mainly due to unskilled technique of pedicle screw fixation, implant defect in design and so on. CONCLUSIONS: The complications associated with the technique of pedicle screw fixation must not be neglected. The main causes are laid on unskilled technique of pedicle screw fixation and implant defect in design.
Keywords:
本文献已被 维普 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号