首页 | 本学科首页   官方微博 | 高级检索  
检索        

巩膜睫状体光凝术治疗恶性青光眼睫状环阻滞解除后高眼压
引用本文:田丹丹,李晶明,宋艳敏,樊小娟,陈丽,秦莉.巩膜睫状体光凝术治疗恶性青光眼睫状环阻滞解除后高眼压[J].国际眼科杂志,2021,21(2):348-350.
作者姓名:田丹丹  李晶明  宋艳敏  樊小娟  陈丽  秦莉
作者单位:中国陕西省西安市,西安交通大学第一附属医院眼科,中国陕西省西安市,西安交通大学第一附属医院眼科,中国陕西省西安市中医医院眼科,中国陕西省西安市,西安交通大学第一附属医院眼科,中国陕西省西安市,西安交通大学第一附属医院眼科,中国陕西省西安市,西安交通大学第一附属医院眼科
摘    要:目的:探讨经巩膜睫状体光凝治疗恶性青光眼睫状环阻滞解除后高眼压的短期与中期有效性和安全性。方法:回顾性研究。收集2016-10/2019-10恶性青光眼睫状环阻滞解除后眼压仍高的患者14例14眼,采用810nm半导体二极管激光经巩膜睫状体光凝术治疗,随访8.36±5.18mo,观察手术前后最佳矫正视力(BCVA)、眼压及并发症情况。结果:治疗后末次随访眼压13.60±3.50mmHg较术前40.53±7.14mmHg有差异(P<0.05);术后末次随访BCVA与术前比较无差异(P>0.05),所有患者至末次随访时无严重并发症。结论:采用810nm半导体二极管激光经巩膜睫状体光凝术治疗恶性青光眼疗效确切,操作简便,并发症少,可有效降低眼压,且对术后BCVA损害较小。

关 键 词:睫状体光凝  恶性青光眼  眼压  视力  并发症
收稿时间:2020/4/30 0:00:00
修稿时间:2021/1/7 0:00:00

Clinical observation of high intraocular pressure after the removal of ciliary ring block in the treatment of malignant glaucoma by scleral cyclophotocoagulation
Dan-Dan Tian,Jing-Ming Li,Yan-Min Song,Xiao-Juan Fan,Li Chen and Li Qin.Clinical observation of high intraocular pressure after the removal of ciliary ring block in the treatment of malignant glaucoma by scleral cyclophotocoagulation[J].International Journal of Ophthalmology,2021,21(2):348-350.
Authors:Dan-Dan Tian  Jing-Ming Li  Yan-Min Song  Xiao-Juan Fan  Li Chen and Li Qin
Institution:Department of Ophthalmology, the First Affiliated Hospital of Xi''an Jiaotong University, Xi''an 710061, Shaanxi Province, China,Department of Ophthalmology, the First Affiliated Hospital of Xi''an Jiaotong University, Xi''an 710061, Shaanxi Province, China,Department of Ophthalmology, Xi''an Hospital of Traditional Chinese Medicine, Xi''an 710021, Shaanxi Province, China,Department of Ophthalmology, the First Affiliated Hospital of Xi''an Jiaotong University, Xi''an 710061, Shaanxi Province, China,Department of Ophthalmology, the First Affiliated Hospital of Xi''an Jiaotong University, Xi''an 710061, Shaanxi Province, China and Department of Ophthalmology, the First Affiliated Hospital of Xi''an Jiaotong University, Xi''an 710061, Shaanxi Province, China
Abstract:AIM: To investigate the short-term and mid-term effectiveness and safety of transscleral ciliary body photocoagulation in the treatment of high intraocular pressure after the removal of malignant glaucoma ciliary ring block.

METHODS: Retrospective study. A collection of 14 eyes of 14 patients with high intraocular pressure after ciliary ring block was lifted from 2016-10/2019-10 malignant glaucoma were treated with 810nm semiconductor diode laser transscleral ciliary photocoagulation. Follow-up 8.36±5.18mo, observation Best corrected visual acuity(BCVA), intraocular pressure and complications before and after surgery.

RESULTS: The intraocular pressure of 13.60±3.50mmHg at the last follow-up after treatment was different from 40.53±7.14mmHg before operation(P<0.05); there was no difference between the BCVA at the last follow-up postoperative and preoperative(P>0.05). All patients had no difference to the last follow-up and serious complications.

CONCLUSION: The 810nm semiconductor diode laser transscleral ciliary body photocoagulation is effective in the treatment of malignant glaucoma. It is easy to operate, has fewer complications, can effectively reduce intraocular pressure, and has little damage to the best corrected vision after surgery.

Keywords:photocoagulation of the ciliary body  postoperative malignant glaucoma  intraocular pressure  viual acuity  complications
本文献已被 维普 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号