首页 | 本学科首页   官方微博 | 高级检索  
检索        

晶状体矢高对有晶状体眼后房型人工晶状体植入术后拱高的影响
引用本文:王静,汪卓赟,徐婷,陶黎明.晶状体矢高对有晶状体眼后房型人工晶状体植入术后拱高的影响[J].国际眼科杂志,2021,21(2):377-381.
作者姓名:王静  汪卓赟  徐婷  陶黎明
作者单位:中国安徽省合肥市,安徽医科大学第二附属医院眼科,中国安徽省合肥市,安徽医科大学第二附属医院眼科,中国安徽省合肥市,安徽医科大学第二附属医院眼科,中国安徽省合肥市,安徽医科大学第二附属医院眼科
基金项目:安徽省教育厅高等学校省级质量工程项目(No.2019sjjd86); 安徽医科大学第二附属医院临床培育计划(No.2020LCZD09)
摘    要:目的:研究眼前节光学相干断层扫描(AS-OCT)所测量的晶状体矢高(CLR)与眼前节参数的关系,及CLR对有晶状体眼后房型人工晶状体植入术(PPC-ICL)术后拱高的影响。方法:本次研究为回顾性研究。选取2017-07/2018-07在安徽医科大学第二附属医院眼科行PPC-ICL患者40例80眼,采用超声生物显微镜测量眼的水平睫状沟直径(hSTS)及晶状体曲率(LC),Pentacam眼前节分析仪测量水平白到白直径(hWTW)、前房深度(ACD)及术后拱高。AS-OCT测量CLR和水平径线的两虹膜角膜夹角连线(ATA)。结果:CLR与ACD(r=-0.706,P<0.01)、术后1a的拱高(r=-0.509,P<0.01)负相关,CLR与LC正相关(r=0.667,P<0.01),与hWTW(r=0.123,P=0.275)、ATA(r=0.208,P=0.065)、hSTS(r=0.147,P=0.194)无相关性,而ACD与术后1a拱高有正相关性(r=0.680,P<0.01)。结论:CLR与ACD、LC有明显相关性,对PPC-ICL术后拱高的预测有一定作用。

关 键 词:近视  有晶状体眼人工晶状体植入术  晶状体矢高  拱高
收稿时间:2020/4/23 0:00:00
修稿时间:2020/12/30 0:00:00

Effect of crystalline lens rise on the vault after implantation of phakic posterior chamber implantable collamer lens
Jing Wang,Zhuo-Yun Wang,Ting Xu and Li-Ming Tao.Effect of crystalline lens rise on the vault after implantation of phakic posterior chamber implantable collamer lens[J].International Journal of Ophthalmology,2021,21(2):377-381.
Authors:Jing Wang  Zhuo-Yun Wang  Ting Xu and Li-Ming Tao
Institution:Department of Ophthalmology,the Second Affiliated Hospital of Anhui Medical University, Hefei 230601, Anhui Province, China,Department of Ophthalmology,the Second Affiliated Hospital of Anhui Medical University, Hefei 230601, Anhui Province, China,Department of Ophthalmology,the Second Affiliated Hospital of Anhui Medical University, Hefei 230601, Anhui Province, China and Department of Ophthalmology,the Second Affiliated Hospital of Anhui Medical University, Hefei 230601, Anhui Province, China
Abstract:AIM:To investigate the relationship between crystalline lens rise(CLR)measured by anterior segment-optical coherence tomography(AS-OCT)and parameters of the anterior segment. And also measure the effects of CLR on the vault after phakic posterior chamber implantable collamer lens(PPC-ICL)implantation.

METHODS:The study included 80 eyes of 40 patients who underwent PPC-ICL implantation at the Department of Ophthalmology, the Second Affiliated Hospital of Anhui Medical University, from July 2017 to July 2018, to measure the sulcus-to-sulcus(hSTS)distance of the eyes using a Compact Touch STS ultrasound biomicroscope and lens curvature(LC), Pentacam was used to measure horizontal-white-to-white(hWTW), anterior chamber depth(ACD)and the vault one year after the operation. Moreover, AS-OCT was used to measure the CLR and horizontal iridocorneal angle-to-iridocorneal angle diameter(ATA).

RESULTS:CLR was negatively correlated with ACD(r= -0.706, P<0.01)and vault one year after the operation(r= -0.509, P<0.01); however, it was positively correlated with LC(r=0.667, P<0.01). There was no correlation between CLR and hWTW(r=0.123, P=0.275), ATA(r=0.208, P=0.065)and hSTS(r=0.147, P=0.194). One year after the operation, there was a positive correlation between the vault and ACD(r=0.680, P<0.01).

CONCLUSION:CLR has obvious correlation with ACD and LC, arch height after PPC-ICL and has a specific effect on the prediction of the vault after PPC-ICL implantation.

Keywords:myopia  phakic posterior chamber implantable collamer lens  crystalline lens rise  vault
本文献已被 维普 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号