首页 | 本学科首页   官方微博 | 高级检索  
检索        

指按法动力学参数的量化测定与比较分析
引用本文:廖彬, 王继红, 黄珊铃, 黄广燊, 陈婉妍.指按法动力学参数的量化测定与比较分析[J].针灸临床杂志,2021,37(1):13-17.
作者姓名:廖彬  王继红  黄珊铃  黄广燊  陈婉妍
作者单位:广州中医药大学针灸康复临床医学院
基金项目:国家自然科学基金,编号:81473792、81873395。
摘    要:目的:通过对不同组别人群指按法动力学参数的量化测定与比较分析,观察其操作是否具有一致性,为指按法的量化与规范化、临床教学提供一定的依据.方法:应用MFF多点薄膜压力测试系统,检测并记录3组不同推拿年限的操作者进行手法操作过程中的动态图形,并保存分析相应的参数数据.结果:3组指按法的平均作用力为本科生组轻度(5.99±2...

关 键 词:指按法  动力学参数  MFF多点薄膜压力测试系统

Quantitative Measurement and Comparative Analysis of Finger-Pressing Manipulation Kinetic Parameters
LIAO Bin,WANG Jihong,HUANG Shanling,HUANG Guangshen,CHEN Wanyan.Quantitative Measurement and Comparative Analysis of Finger-Pressing Manipulation Kinetic Parameters[J].Journal of Clinical Acupuncture and Moxibustion,2021,37(1):13-17.
Authors:LIAO Bin  WANG Jihong  HUANG Shanling  HUANG Guangshen  CHEN Wanyan
Institution:(Chinical Colledge of Acupuncture & Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou 510000, China)
Abstract:Objective: To provide a basis for quantification, standardization and clinical teaching of finger-pressing through the quantitative measurement and comparative analysis of the kinetic parameters of the manipulation, and by observing the difference of the manipulation among different groups of operators. Methods: MFF multi-film pressure measurement system was applied to detect and record the dynamic figure of the manipulation among three groups of operators with different years of Tuina practice, and the corresponding parameter data were saved and analyzed. Results: The mean force of the finger-pressing manipulation in the undergraduate group was as follows: mild (5.99±2.47) N, moderate (14.54±3.38) N and strong (23.57±6.31) N;in the postgraduate group was as follows: mild (12.60±2.08) N, moderate (22.45±3.36) N and strong (36.43±5.07) N;in the teacher group was as follows: mild (14.42±1.45) N, moderate (28.81±2.77) N and strong (43.48±3.94) N. In terms of the comparison of the same force type in the student groups, the average force of the boys was greater than that of the girls in the same group;the average force of the boys in the postgraduate group was greater than that of the boys in the undergraduate group and the average force of the girls in the postgraduate group was also greater than that of the girls in the undergraduate group. Conclusion: The difference of the finger-pressing manipulation can be seen by using MFF multi-film pressure measurement system. The individual difference is small in the teacher group, the strength is more stable and lasting, and the grasp of mild, moderate and strong strength is more accurate.
Keywords:Finger-pressing manipulation  Kinetic parameters  MFF multi-film pressure measurement system
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《针灸临床杂志》浏览原始摘要信息
点击此处可从《针灸临床杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号