摘    要:目的:通过回顾分析67例食管金属内支架置入术的并发症原因,探讨预防和处理的方法。方法:1996年6月至2000年8月,对78例食管狭窄患者行金属内支架置入治疗,共置入内支架96八,其中附膜支架59枚,裸支架37枚,对内支架置入术后出现的各种并发症进行分析。结果:78例中67例出现并发症,如胸骨后疼痛、食管胃内容物返流、支架置入后再狭窄或堵塞、支架移位、食管出血、穿孔以及心率失常等。分别给予相应的处理后多数可以得到改善或消失。结果:金属内支架置入治疗食管狭窄所致的并发症是可以预防的,如果出现并发症经过处理可以获得缓解。

关 键 词:食管狭窄 金属内支架 并发症 手术治疗 预防
文章编号:1003-3289(2002)03-0238-02
收稿时间:2001-11-05
修稿时间:2001-11-05

Analysis of Post-Metallic Stent Placement Complications in the Treatment of Esophageal Strictures
DU Tian-hui,LIU Zhi,LI Yuan-yuan and XU Guang-hui. Analysis of Post-Metallic Stent Placement Complications in the Treatment of Esophageal Strictures[J]. Chinese Journal of Medical Imaging Technology, 2002, 18(3): 238-239
Authors:DU Tian-hui  LIU Zhi  LI Yuan-yuan  XU Guang-hui
Affiliation:Department of Radiology, the 251th Hospital of PLA,Zhangjiakou 075000, China;Department of Radiology, the 251th Hospital of PLA,Zhangjiakou 075000, China;Department of Radiology, the 251th Hospital of PLA,Zhangjiakou 075000, China
Abstract:Purpose To analyse the causes of complications that occurred in the 67 patients treated by metallic stent implanation,in order to study the prevention and treatment. Methods From June 1996 to August 2000,96 metallic stents were used for 78 patients with esophageal strictures. Covered stents ( n =59) and uncovered stents ( n =37) were chosen.Postoperative complications were analysed. Results Sixty seven cases of the 78 patients were complicated with chest pain, gastroesophageal regurgitation, postoperative recurrent stenosis,stent migration,esophagorrhagia esophageal perforation and cardiac arrhythmia.These symptoms disappeared or were relieved mostly by treatment. Conclusion The post stent placement complications in the treatment of esophageal strictures are preventable and can be rilieved by treatment if they occur.
Keywords:Esophageal stenosis  Metallic stent  Complication  Prevention  Treatment
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号