首页 | 本学科首页   官方微博 | 高级检索  
     

主动与被动电极植入右室心尖部或右室间隔部即刻起搏参数的比较
引用本文:王禹川,丁燕生,周菁,盛琴慧,蒋捷,史力斌,李康. 主动与被动电极植入右室心尖部或右室间隔部即刻起搏参数的比较[J]. 中国心脏起搏与心电生理杂志, 2011, 25(6): 503-505. DOI: 42-1421/R.20111208.1543.011
作者姓名:王禹川  丁燕生  周菁  盛琴慧  蒋捷  史力斌  李康
作者单位:1. 北京大学第一医院老年科 北京 100034
2. 北京大学第一医院心内科 北京 100034
摘    要:目的比较主动与被动电极(AE与PE)植入右室心尖部(RVA)或右室间隔部(RVS)对即刻起搏参数的影响。方法回顾植入永久起搏器的患者资料,比较AE和PE植入RVA时即刻起搏参数的差异,比较AE植入RVA或RVS即刻起搏参数的差异。结果入选399例,283例右室起搏电极植入RVA,AE 155例,PE 128例。AE者的起搏阈值高于PE者,而阻抗、感知低于PE者,电极类型是影响差异的唯一因素。271例右室起搏电极为AE,植入RVA 155例,RVS 116例。两部位仅阻抗有差异,起搏部位是影响差异的唯一因素。结论 AE和PE在植入RVA时起搏阈值、感知和阻抗的差异由电极类型不同所引起,而AE植入RVA和RVS即刻阻抗的差异归咎于起搏部位的不同。

关 键 词:心血管病学  主动电极  被动电极  右室心尖部  右室间隔  即刻起搏参数

The compares of instant pacing parameters between active electrode and passive electrode when inserted them into right ventricular apex or right ventricular septum
WANG Yu-chuan,DING Yan-sheng,ZHOU Jing,SHENG Qin-hui,JIANG Jie,Shi Li-bin,LI Kang. The compares of instant pacing parameters between active electrode and passive electrode when inserted them into right ventricular apex or right ventricular septum[J]. Chinese Journal of Cardiac Pacing and Electrophysiology, 2011, 25(6): 503-505. DOI: 42-1421/R.20111208.1543.011
Authors:WANG Yu-chuan  DING Yan-sheng  ZHOU Jing  SHENG Qin-hui  JIANG Jie  Shi Li-bin  LI Kang
Affiliation:b. a Department of Geriatrics;b Department of Cardiology,First Hospital of Peking University,Beijing 100034,China
Abstract:Objective To compare the difference of the instant pacing parameters(IPPs) when inserted active electrode (AE) or passive electrode(PE) into right ventricular apex( RVA), and when inserted AE into RVA or right ventricular septum(RVS). Methods To review patients' data who received pacemaker implantation in our hospital. The statistics of the IPPs weIe analyzed when the AE was inserted into the RVA or RVS, as well as the AE or the PE was inserted into the RVA. Rt~ults Three hundred and ninety-nine patients were reviewed. There were 283 patients that the right ven- tricular electrode was inserted into the RVA. Among them, the AE was used in 155 patients while the PE was used in the others. The higher threshold was found in AE group, while the higher impedance and sensing were found in PE group. The type of electrode was the only impact factor. There were 271 patients with AE. The position of electrode insertion was at RVA in 155 patients and at RVS in the others. In two groups, the only significant difference of IPPs was found in imped- ance, and the position of electrode insertion was the impact factor. Conclusions When AE or PE is inserted into RVA, the differences in threshold, sensing and impedance are found between AE group and PE group which is attributed to the difference of electrode type. When AE is inserted into RVA or RVS, the impedance is the only difference which is attributed to the difference in pacing position.
Keywords:Cardiology  Active electrode  Passive electrode  Right ventricular apex  Right ventricular septum  Instant pacing parameter
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏