Effect of a capsular tension ring on prevention of intraocular lens decentration and tilt and on anterior capsule contraction after cataract surgery |
| |
Authors: | Minehiro Takimoto Ken Hayashi Hideyuki Hayashi |
| |
Institution: | (1) Hayashi Eye Hospital, Fukuoka, Japan;(2) Department of Ophthalmology, School of Medicine, Fukuoka University, Fukuoka, Japan;(3) Hayashi Eye Hospital, 4-23-35 Hakataekimae, Hakata-ku, Fukuoka 812-0011, Japan |
| |
Abstract: | Purpose To investigate the effect of a capsular tension ring (CTR) on the prevention of marked decentration and tilt of the intraocular
lens (IOL), severe anterior capsule contraction, and refractive prediction error after cataract surgery.
Methods Forty-seven eyes of 43 patients that had an implantation of a CTR during phacoemulsification surgery due to zonular instability
(CTR group), and 34 fellow eyes that did not receive a CTR (no-CTR group) were enrolled. The degree of IOL decentration and
tilt and the anterior capsule opening area were measured using a Scheimpflug videophotography system.
Results No significant differences were found between the two groups in the mean degree of IOL decentration (0.34 mm in the CTR group,
0.29 mm in the no-CTR group; P = 0.1401), tilt angle (2.82° in the CTR group, 2.56° in the no-CTR group; P = 0.3173), anterior capsule opening area (24.3 mm2 in the CTR group, 23.6 mm2 in the no-CTR group; P = 0.7620), or refractive prediction error (P = 0.3459).
Conclusion In eyes with either zonular dehiscence or weakness, a CTR can prevent marked IOL decentration and tilt and severe anterior
capsule contraction, and may lead to prevention of refractive prediction error. |
| |
Keywords: | anterior capsule contraction capsular tension ring cataract surgery intraocular lens decentration and tilt refractive prediction error |
本文献已被 PubMed SpringerLink 等数据库收录! |
|