首页 | 本学科首页   官方微博 | 高级检索  
检索        


Comparison of the diagnostic performances of diffusion parameters in diffusion weighted imaging and diffusion tensor imaging of breast lesions
Authors:Ozgur Cakir  Arzu Arslan  Nagihan Inan  Yonca Anık  Tahsin Sarısoy  Sevtap Gumustas  Gur Akansel
Institution:Kocaeli University Faculty of Medicine, Department of Radiology, 41380 Kocaeli, Turkey
Abstract:

Purpose

To evaluate the diagnostic efficiency of the diffusion parameters measured by conventional diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) for discrimination of malignant breast lesions from benign lesions and the normal breast.

Materials and methods

The study included 52 women with 55 breast lesions (30 malignant, 25 benign). DTI and DWI were performed complementary to dynamic contrast MRI at 3T. Apparent diffusion coefficient (ADC) of DWI, mean diffusivity (MD) and fractional anisotropy (FA) values of DTI were measured for lesions and contralateral breast parenchyma in each patient. We used b factors of 0, 50, 850, 1000 and 1500 s/mm2 for DWI and b 0 and 1000 s/mm2 for DTI. ADC, MD and FA values were compared between malignant and benign lesions, and the normal parenchyma by univariate and multivariate analyses.

Results

Diffusion parameters showed no difference according to menopausal status in the normal breast. ADC and MD values of the malignant lesions were significantly lower than benign lesions and normal parenchyma (p = 0.001). The FA showed no statistical significance. With the cut-off values of ≤1.23 × 10−3 mm2/s (b 0–1000 s/mm2) and ≤1.12 × 10−3 mm2/s (b 0–1500 s/mm2), ADC showed 92.85% and 96.15% sensitivity; 72.22% and 73.52% PPV, respectively. With a cut-off value of ≤1.27 × 10−3 mm2/s (b 1000 s/mm2), MD was 100% sensitive with a PPV of 65.90%. Comparing the diagnostic performance of the parameters in DTI with DWI, we obtained similar efficiency of ADC with b values of 0,1000 and 0,1500 s/mm2 and MD with a b value of 0, 1000 s/mm2 (AUC = 0.82 ± 0.07).

Conclusion

ADC of DWI and MD of DTI values provide significant discriminative factors for benign and malignant breast lesions. FA measurement was not discriminative. Supported with clinical and dynamic contrast MRI findings, DWI and DTI findings provide significant contribution to the final radiologic decision.
Keywords:Mean diffusivity  MD  Fractional anisotropy  FA  Diffusion tensor imaging  DTI  Apparent diffusion coefficient  ADC  Diffusion weighted imaging (DWI)  Breast cancer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号