多层螺旋CT心电门控冠状动脉重建对冠心病的诊断价值
引用本文:谭洪文,杨天和,蔡运昌,何强,方颖.多层螺旋CT心电门控冠状动脉重建对冠心病的诊断价值[J].贵州医药,2006,30(4):303-306.
作者姓名:谭洪文  杨天和  蔡运昌  何强  方颖
作者单位:1. 贵州省人民医院心内科,贵阳,550002
2. 贵州省人民医院放射科,贵阳,550002
3. 贵阳医学院附属医院心内科,550004
摘    要:目的评价16层螺旋CT用于诊断冠心病的价值。方法对28例临床诊断或疑似冠心病患者进行16层螺旋CT心电门控平扫及增强扫描,以选择性冠状动脉造影结果为对照,初步评价多层螺旋CT冠脉成像用于诊断冠心病的敏感度、特异度、阳性预测值、阴性预测值和准确度。结果 16层螺旋CT冠脉造影用于诊断冠心病的敏感度为80.0%、特异度为91.4%、阳性预测值为77. 4%、阴性预测值为92.6%、准确度为88.4%。结论 16层螺旋CT冠状动脉造影是一种无创、简便的冠脉成像方法,对冠心病的诊断有较高的准确性,可作为冠心病的筛选方法。

关 键 词:冠心病  多层螺旋CT  冠状动脉血管造影术
文章编号:1000-744X(2006)04-0303-04

The evaluation of diagnostic value for coronary heart disease with muti-slice spiral CT
Tan Hongwen, Yang Tianhe, Cai Yunchang,et al..The evaluation of diagnostic value for coronary heart disease with muti-slice spiral CT[J].Guizhou Medical Journal,2006,30(4):303-306.
Authors:Tan Hongwen  Yang Tianhe  Cai Yunchang  
Institution:Tan Hongwen, Yang Tianhe, Cai Yunchang, et al.
Abstract:Objective To evaluate the value of sixteen-slice spiral CT in diagnosis of coronary heart disease. Methods Sixteen-slice spiral CT scanning were performed in 28 patients with known or suspected coronary heart disease. As compared with selective coronary angiography, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of sixteen-slice spiral CT coronary angiography in diagnosing coronary artery disease were primarily evaluated. Results The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of sixteen-slice spiral CT coronary angiography were 80. 0%,91. 4%,77. 4%,92. 6% and 88. 4%, respectively. Conclusion The sixteen-slice spiral CT coronary angiography is a noninvasive and simple imaging technique, and it has the potential screening value for coronary heart disease with high accuracy.
Keywords:Coronary heart disease Multi-slice spiral computed tomography Coronary angiography