首页 | 本学科首页   官方微博 | 高级检索  
检索        

腹主动脉瘤腔内隔绝术相关器械及其应用技术
引用本文:赵珺,景在平,王振堂,王永春,任建,沈倩瑾,蔡希刚,陆美中.腹主动脉瘤腔内隔绝术相关器械及其应用技术[J].中国医学影像技术,2001,17(12):1133-1135.
作者姓名:赵珺  景在平  王振堂  王永春  任建  沈倩瑾  蔡希刚  陆美中
作者单位:1. 上海长海医院血管外科暨全军血管外科研究所,放射科导管室,
2. 上海长海医院血管外科暨全军血管外科研究所,
基金项目:全军杰出人才基金(98J005)及上海卫生系统百人计划基金(9 7BR047)资助项目.
摘    要:目的:探讨腹主动脉瘤(AAA)腔内隔绝术(EVE)相关器械的应用技术。方法:对85例肾下腹主动脉瘤患者进行了腔内隔术,主要采用主体-单肢嵌接式移植物,相关器械主要有DSA及附属设备,各种造影导管,多用途导管、导丝、圈套器、球囊等。采用双侧腹股沟下方纵切口,经股总动脉将输送器导入预定位置,释放移植物,在瘤腔内将移植物单肢与主体连接形成分叉型新的血流通道,将动脉瘤隔绝。根据术中不同情况采用上述介入器械。结果采用球囊导管扩张8例,加用裸支架3例,钢圈栓塞右侧髂内动脉6例,应用鹅颈圈套器将导丝从主体侧牵入接口侧股动脉3例,使用多用途导管帮助导丝跨越移植物分叉5例,在接口侧帮助导丝定向3例。结论:EVE对设备及导管技术操作要求非常高,备足各种系列各种类型常规介入器具对保证EVE的技术成功率有非常重要的意义。

关 键 词:动脉瘤  腹部  介入  外科手术
文章编号:1003-3289(2001)12-1133-03
收稿时间:2001/9/20 0:00:00
修稿时间:2001年9月20日

Equipment and the Techniques in the Procedure of Endovascular Exclusion for Abdominal Aortic Aneurysm
ZHAO Jun,JING Zai-ping,WANG Zhen-tang,WANG Yong-chun,REN Jian,SHEN Qian-jin,CAI Xi-gang and LU Mei-zhong.Equipment and the Techniques in the Procedure of Endovascular Exclusion for Abdominal Aortic Aneurysm[J].Chinese Journal of Medical Imaging Technology,2001,17(12):1133-1135.
Authors:ZHAO Jun  JING Zai-ping  WANG Zhen-tang  WANG Yong-chun  REN Jian  SHEN Qian-jin  CAI Xi-gang and LU Mei-zhong
Institution:Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China;Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China;Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China;Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China;Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China;Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China;Department of Vascular Surgery, Changhai Hospital, Second Military Medical University, the Institute of Vascular Surgery of PLA, Shanghai 200433, China
Abstract:Purpose To discuss the usage of equipment and techniques for the procedure of abdominal aortic aneurysms treated by endovascular exclusion. Methods Eighty five patients with infra renal abdominal aortic aneurysms received endovascular stent graft exclusions. The stent garfts used were body to limb combined styles. The interrelated instruments were the fluoroscopic equipment, series of angiographic catheters, multi usable catheters, guide wires, snares, balloons, etc. After the longitudinal incisions inferior to both sides of the groin, the common femoral arteries were exposed, and the delivery systems were inserted to the target region. After the deployment of the stent grafts, the limb was connected with the mainbody, and a bifurcated graft that made the new blood canal excluded the aneurysm sac with the blood flow. The equipment above was used to fit the needs of different conditions in the procedure. Results Eight cases received the ballooning. Three cases needed the bare stents for limb restriction. Coiling of the right internal iliac artery was needed in six cases. Goose neck snares were used in three cases to retreat the wire into the bilateral femoral artery. Multi usable catheters were used in five cases to assist the wire crossing the bifurcation of the stent grafts, and in three to locate the wire to penetrate into the connecting segment. Conclusion Endovascular stent graft exclusion needs high skills of catheter techniques. Abundant of convenient intervention equipment is significantly helpful for the success of the procedure.
Keywords:Aneurysm  Abdominal  Operation  Intervention
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息